![Topcon OS-101 Скачать руководство пользователя страница 82](http://html1.mh-extra.com/html/topcon/os-101/os-101_instruction-manual_1128653082.webp)
15. RESECTION MEASUREMENT
76
Resection calculation process
The NE coordinates are found using angle and distance observation equations, and the
instrument station coordinates are found using the method of least squares. The Z coordinate
is found by treating the average value as the instrument station coordinates.
Calculated instrument
station coordinates set
as hypothetical coordinates