![Topcon OS-101 Скачать руководство пользователя страница 48](http://html1.mh-extra.com/html/topcon/os-101/os-101_instruction-manual_1128653048.webp)
10. CONNECTING TO EXTERNAL DEVICES
42
Set Comms mode in the "Comms setup" tab to
"
Bluetooth
".
• Changing communication settings during
Bluetooth
communication will cancel the
connection.
• The
status bar icon cannot be tapped in
<Communication Setup>.
• No changes for the setting' (2) to (4) from the
factory setting are necessary as long as
connecting to a recommended program on the
data collector. If connection can not be
established, check the communication settings
of OS and the data collector.
• Setting’ (3) and (4) are for an instrument using
GTS commands.
Items set and options (*: Factory setting)
(1) Communication mode RS232C*/
Bluetooth
(2) Check sum
yes/No*
(3) Terminate
ETX*/ETX+CR/ETX+CR+LF
(4) Ack mode
Off/On*
Terminate
Select the option Off or On for carrige return (CR) and line feed when collecting measurement
data with a computer.
ACK mode
When communicating to an external device, the protocol for handshaking can omit the
[ACK]
coming from the external device so data is not sent again.
On:
Standard
Off:
Omit the
[ACK]
2. Check that "Mode" in the "
Bluetooth
" tab is set to
"Slave".
• Only "Slave" can be selected when the
instrument is shipped.