4-17
4 PROGRAM MODE
Job Manager (Page 2)
Page two of the Job Manager menu provides the options to Transfer Jobs, Rename a Job, Delete a Job,
or Delete All Jobs.
The transfer data option sends and receives coordinates to and from the computer. The
communications parameters are set by the user for Protocol, Baud rate, Parity, and Stop bits. Topcon‘s
interface cable from the GTS-600 to the computer is used for the data transfer.
Job names can be renamed by using the Rename a Job option. When the rename option is selected,
the current job will be renamed unless you select a different job using the View Memory option.
There are two options to delete jobs in memory, Delete a Job and Delete All Jobs. The Delete a Job
option will delete one job from memory. The current job is erased unless another job is selected using
the View Memory option. The Delete All Jobs option will erase all the jobs in memory.
Transfer Jobs
The protocol default parameters are highlighted on the GTS-600 series.
The Transfer Jobs option will send and receive jobs to and from the PC. In the receive option, the
software in the instrument will not allow the new job from the PC to overwrite the current job. A warning
“Coordinate data file already exists” will appear when receiving the job from the PC. If you select (YES),
the current job is erased and the job received from the PC is added to memory. If you select (NO), a
message appears to receive another job without erasing the current job. This will add the new job to
memory and the received job becomes the current job.
The send option will transfer jobs from the instrument to the PC. The current job will be sent to the PC
unless you select another job.
COMM Protocol
Before sending and receiving jobs to the instrument, the protocol parameters on the instrument should
be checked. Make sure the protocol parameters match the PC software.
Protocol: ACK/NAK
Baud rate:9600
Parity :8/None
Stop bits:1