Topcom Digital Thermometer 100 Скачать руководство пользователя страница 1

TOPCOM - Digital Thermometer 100

MD1060247/UK V1.1

TOPCOM - Digital Thermometer 100 - User Guide 

ENGLISH

1

Introduction

Congratulations on the purchase of the Topcom Digital Thermometer 100. We hope you 
will enjoy using the thermometer and the benefits it offers. 

2

Safety notes

This thermometer is intended for household use only. The use of this thermometer is 
not intended as a substitute for physician’s consultation.

This product is not a toy. 

The thermometer should only be used under the supervision of an adult. 

Do not walk, run or talk during temperature taking. 

Clean the thermometer before and after each use. 

Store the unit in the protective case and keep away from children when not in use. 

Do not bite the probe and battery cover. 

Do not store the unit where it will be exposed to direct sunlight, dust or humidity. 
Avoid extreme temperatures. 

Dropping or subjecting your thermometer to strong shocks should be avoided. 

Do not attempt to dissemble the unit, except to replace the battery. 

The body of the thermometer should be free of crack before use. 

Do not use if battery cover is detached. 

If measurement is not attainable, the unit must be replaced. 

3

What you need to know about your body temperature

Although the generally accepted "normal" temperature reading is 37.0°C, temperature 
reading can vary from 36°C to 37.3°C and still may be considered as "normal". 
Your body temperature can be influenced by your activities such as exercise, smoking, 
eating and drinking. 
Even time of day may influence your body temperature. For example, your temperature is 
lower in the morning than in the afternoon. 
Other variations may be due to the location of the temperature reading. 
While the oral temperature follows the guidelines previously described, a rectal 
temperature is generally 0.5°C higher. Conversely, an auxiliary (under the arm) 
temperature will be 0.5°C lower. 

4

Description

1.

Sensor

2.

Flexible tip

3.

LCD display

4.

ON - OFF button

5.

Battery cover

5

Battery installation

When the battery low icon 

 is displayed, the battery needs to be replaced.

Remove the small screw on the backside of the 
thermometer.

Pull the battery cover (5) away from the thermometer.

Use a non-metallic pointed object to remove the old 
battery. 

Place a new 1,5V DC battery (L736, SR41, LR41, 392 or 
192) with the negative pole (-) side up and the positive 
pole (+) facing down in battery compartment.

Put the battery cover back on the thermometer and re-
install the screw.

6

Measurement

6.1

Important before use

When the temperature is higher than 38°, means that the patient may have fever. 
Contact your doctor.

It is important to clean your Thermometer before the first time of use and after each 
application. Clean your Digital Thermometer by wiping it with soap and water or 70% 
isopropyl Alcohol otherwise the result of measurement will be inaccurate.

The thermometer is calibrated and does not need re-calibration if used according to 
the instructions.

After a shower or exercise, the body temperature will rise. Please take a rest before 
taking temperature.

6.2

Taking an Oral Temperature 

Drinking hot or cold fluids, exercising, smoking or 
performing other activities may raise or lower your 
temperature. Therefore, it is important to relax for 
approximately 5 minutes with your mouth closed prior to 
taking a reading.

Place the probe tip under the tongue as near as 
possible to the heat pocket. The diagram also shows 
the temperature variables by not placing the tip in the 
heat pocket area. 

Close the mouth

Press the ON/OFF button (4) briefly. After all segments have been displayed, the 
previous result or ‘Lo’ is displayed for 2 seconds.

The thermometer starts measurement.

When the temperature stabilizes at peak temperature, 10 beeps are audible and the 
result is displayed.

If the temperature is above 37.8 C, the unit will sound ten sets of two short beeps. 

Press the ON/OFF button (4) to turn the unit off or the unit will automatically shut off 
after approximately ten minutes. 

6.3

Axillary use

Wipe the underarm with a dry towel. 

Place the probe tip under the arm so the tip is touching the skin with the 
thermometer perpendicular to the body. 

Position the arm across the chest so the probe tip is well covered by the arm. This 
also insures the probe is not affected by the room's air. 

Press the ON/OFF button (4) briefly. After all segments have been displayed, the 
previous result or ‘Lo’ is displayed for 2 seconds.

The thermometer starts measurement.

When the temperature stabilizes at peak temperature, 10 beeps are audible and the 
result is displayed.

If the temperature is above 37.8 C, the unit will sound ten sets of two short beeps. 

Press the ON/OFF button (4) to turn the unit off or the unit will automatically shut off 
after approximately ten minutes.

6.4

Rectal use

After applying the disposable probe cover, apply a water-soluble lubricant to the tip. 

Do not use petroleum jelly like Vaseline for easier insertion.

Gently insert the probe a MAXIMUM of 1 cm into the rectum.

Press the ON/OFF button (4) briefly. After all segments have been displayed, the 
previous result or ‘Lo’ is displayed for 2 seconds.

The thermometer starts measurement.

When the temperature stabilizes at peak temperature, 10 beeps are audible and the 
result is displayed.

If the temperature is above 37.8 C, the unit will sound ten sets of two short beeps. 

Press the ON/OFF button (4) to turn the unit off or the unit will automatically shut off 
after approximately ten minutes.

7

Disposal of the device (environment)

At the end of the product lifecycle, you should not throw this product into the 
normal household garbage but bring the product to a collection point for the 
recycling of electrical and electronic equipments. The symbol on the product, 
user guide and/or box indicate this.
Some of the product materials can be re-used if you bring them to a recycling 

point. By re-using some parts or raw materials from used products you make an important 
contribution to the protection of the environment. Please contact your local authorities in 
case you need more information on the collection points in your area.

Batteries must be removed before disposing of the device.
Dispose of the batteries in an environmental manner according to your 
country regulations.

8

Specifications

Global Treasure Industries Ltd. Room.8, 5/F, Block 2, Nan Fung Ind. City, No. 18 
Tin Hau Road, Tuen Mun, N.T., Hong Kong

Topcom Europe NV, Grauwmeer 17, 3001 Heverlee, Belgium

Read this manual carefully before use. For specific information on your own 
body temperature, contact your physician. Put the user guide away in a safe 

place for future reference.

To avoid inaccurate results caused by electromagnetic interference 
between electrical and electronic equipments, do not use the device near 
a cell phone or microwave oven.

3

4

The mouth must remain closed during the measurement for the most 
accurate reading. Opening the mouth could result in an extended 
measurement time and may affect the reading.

Measuring range
Accuracy
Resolution
Working conditions

Storage conditions 

Battery 

Battery Life
Auto shut off
Dimension
Weight

Classification 

32,0 ~ 42,9°C
+/- 0,1°C
0,1°C
Temperature 10 ~ 40°C
Humidity 15 ~ 95% RH
Temperature -10 ~ 60°C
Humidity 15 ~ 95% RH
1 x 1,5V DC Alkaline Manganese 
L736, SR41, LR41, 392 or 192
Approximately 1500 measurements
After approximately 10 minutes
147 x 25 x 19mm
Approx. 17 grams with battery inside

Internally powered equipment

Protection against electric shock - type B 

IPX0

Not suitable for use in presence of flammable 
anaesthetic mixture with air or with oxygen or 
nitrous oxide

Continuous operation with short-time loading

Method of sterilizing or disinfection recommended 
by the manufacturer - Disinfection

It is suggested that a rectal used themometer is separated from a axillary 
or oral used thermometer because of hygienic reason.
Rectal temperatures are an appropriate and reliable method for infants 
and small children. Otherwise, this method should only be used when it 
is impossible or impractical to take an oral or auxiliary temperature.

 

0123

This product is in compliance with the essential requirements and other 

relevant provisions of the directive 93/42/EEC.

The Declaration of conformity can be found on : 

http://www.topcom.net/cedeclarations.asp.php

EC

REP

Содержание Digital Thermometer 100

Страница 1: ...probe tip under the arm so the tip is touching the skin with the thermometer perpendicular to the body Position the arm across the chest so the probe tip is well covered by the arm This also insures t...

Страница 2: ...oek Plaats de punt van de sonde onder de oksel zodat de punt de huid raakt met de thermometer loodrecht op het lichaam Plaats de arm over de borst zodat de punt van de sonde goed door de arm wordt bed...

Страница 3: ...ssuyer son aisselle l aide d une serviette s che Placer la sonde sous le bras de sorte que le bout soit en contact avec la peau et que le thermom tre soit perpendiculaire au corps Positionner son bras...

Страница 4: ...temperatur Wischen Sie den Achselbereich mit einem trockenen Handtuch ab Platzieren Sie die F hlerspitze so unter dem Arm dass diese die Haut ber hrt und das Thermometer senkrecht zum K rper liegt Leg...

Страница 5: ...debajo del brazo de manera que est en contacto con la piel y el term metro quede perpendicular al cuerpo El brazo debe cruzar el pecho para que la punta de la sonda quede totalmente cubierta De este...

Страница 6: ...rt Torka armh lan med en torr handduk Placera sondspetsen i armh lan s att spetsen ligger an mot huden och med termometern i lodr t position l ngs kroppen L gg armen ver br stet s att sondspetsen t ck...

Страница 7: ...uden og termometret er lodret p kroppen Positioner armen p tv rs af brystet s spidsen d kkes godt af armen Dette sikrer at f leren ikke p virkes af rummets temperatur Tryk kortvarigt p T nd sluk knapp...

Страница 8: ...asser sondetuppen i armhulen slik at tuppen ber rer huden og termometeret ligger rett opp fra kroppen Legg armen over brystet slik at sondetuppen er helt dekket av armen Dette sikrer ogs at sonden ikk...

Страница 9: ...rki koskettaa ihoa kuumemittari kohtisuorassa vartaloon n hden Aseta k sivarsi rinnan poikki niin ett anturin k rki on hyvin k sivarren peitossa T m varmistaa my s sen ettei huoneenl mp tila vaikuta a...

Страница 10: ...o Piegare il braccio davanti al petto in modo da coprire bene il puntale della sonda In questo modo la misurazione non viene influenzata dall aria circostante Premere brevemente il tasto ON OFF 4 Dopo...

Страница 11: ...o do bra o de modo a que a ponta toque na pele e o term metro esteja perpendicular ao corpo Coloque o bra o sobre o peito de modo que a ponta da sonda fique bem coberta pelo bra o Isto tamb m assegura...

Страница 12: ...aby byl teplom r kolmo k va emu t lu Pa i um st te p es hru aby pa e d kladn p ekr vala pi ku detektoru Takto rovn zajist te e detektor nebude ovlivn n vzduchem v m stnosti Kr tce stiskn te tla tko Z...

Страница 13: ...4 _ _ _ _ _ _ _ _ 6 3 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 4 _ _ Lo 2 _ _ 10 _ _ 37 8 C _ _ _ _ _ 4 _ _ _ _ _ _ _ _ 6 4 _ 9 _ _ 1 _ _ _ _ 4 _ _ Lo 2 _ _ 10 _ _ 37 8 C _ _ _ _ _ 4 _ _ _ _ _ _ _ _ 7 9 _...

Страница 14: ...gy hogy az rintkezik a b rrel s a l zm r mer leges a testtel Tegye keresztbe a karj t a mell n gy az rz kel t jobban mag hoz szor tja s az kev sb lesz kit ve a leveg h m rs klet nek Nyomja meg r vide...

Страница 15: ...ia a Ustaw r k w poprzek klatki piersiowej tak aby czujnik by dobrze przykryty Dzi ki temu czujnika nie jest zak cany przez przep ywaj ce powietrze Naci nij kr tko przycisk ON OFF 4 Po zapaleniu si ws...

Страница 16: ...ku senzora T m sa taktie zaru e senzor nebude ovplyvnen teplotou okolia Kr tko stla te vyp na 4 Po zobrazen v etk ch segmentov displeja sa na dve sekundy zobraz naposledy nameran teplota alebo indik t...