14.1    

Spare parts

 

 
 
Bb0300000 

Quick fastener 

for case 

Bb0300100 

Quick fastener 

for door switch cabinet 

Ca2000500 

Screwed cap 

for manual fill 

Db0500200 

Gasket for tank cover 

 

Dc0100000 

Castors Ø 50 mm 

with hole for central fixing 

De0100400 

Water filter R 3/8" 

 

Df0200000 

Solenoid valve R 3/8" 

type 21 H7, for water cooling 

Df0200100 

Solenoid valve R 1/4" 

type 21 A2, for autom. refill and drainage 

Df0200600 

Spare coil for solenoid valve 

R 3/8" type 21 H7 and R 1/4" type 21 A2 

Df0200900 

Repair kit for solenoid valve 

R 1/4" Typ 21 A2, consisting of: tappet 

Df0200901 

Repair kit for solenoid valve 

R 3/8" Typ 21 H7, consisting of: membrane, spring, tappet 

Fa0800000 

Controller MP-694 FeKo 

self-optimizing, new 

Fa0800001 

Controller MP-694 FeKo 

self-optimizing, in exchange 

Gb0100400 

Contactor 

32 A, LC1 D1801 P7, 220 V (3 x 380/415 V / 3 x 220 V) 

Gb0101000 

Contactor 

40 A, LC1 D2501 P7, 220 V (3 x 220 V) 

Gb0700800 

Thermal relay 

2,5 - 4,0 A (3 x 220 V), LR2D 1308 

Gb0701700 

Thermal relay 

1,6 - 2,5 A (3 x 380/415 V), LR2D 1307 

Gc0100600 

Transformer 70 VA 

415/380/220 V - 220 V, standard 

Gf0101200 Capillary 

thermostat 

80-370°C 

Gg0300000 

Horn 

with intermittent and continuous sound 

Gi0100000 Level 

switch 

microswitch 

Gk0200000 VAC-switch 

for leakstopper device, with 2 switching levels, complete 
(only for TT-155 and 156 E) 

Gk0200100 

VAC-switch 

with 3 switching levels, complete, front and back part 

Gk0200200 

VAC-switch 

only front part with red handle 

Gk0300300 

Indication lamp 

yellow, 33 x 25 mm 

Gk0300600 

Double switch 

green, 33 x 25 mm, for heating 

Gk0300700 

Switch 

green, 33 x 25 mm, for ON/OFF and horn 

Gk0500100 

Press button 

green, for automatic mould drainage 

Gl0200000 

Fuses, small 

5 x 20 mm, 1 A (packet of 10 pieces) 

Gl0200001 

Fuse carrier, big 

6,5 x 32 mm,  for transformer 

Gl0200002 

Fuse carrier, small 

5 x 20 mm, for transformer 

Gl0200003 

Fuses, big 

6,5 x 32 mm, 1 A (packet of 10 pieces) 

 

Heating 3000 W 

indicate voltage 

Wa1000000 

Thermocouple 

internal Fe-Ko, length 1000 mm 

Wa1000001 

Thermocouple 

internal Pt-100, length 1000 mm 

Wc0100000 

Heat exchanger 

model TT-157 (also for TT-140 Sm, 150 G, 150 F, 155 E, 156 E) 

Wd0100000 

Float 

with 4 set collars 

Wd0215701 

Pipe to mould 

pump – unit outlet, including cutting ring and union nut 

Wd0215702 

Pipe from mould 

unit inlet – tank, including cutting ring and union nut 

Wd0215711 

Pipe cooling water outlet 

tank – rear side of unit, including cutting ring and union nut 

Wd0215712 

Pipe cooling water inlet 

rear side of unit – solenoid valve R 3/8" 
including cutting ring and union nut 

Wd0215713 

Pipe cooling water inlet 

solenoid valve R 3/8" – heat exchanger 
including cutting ring and union nut 

Wf0100000 Insulation 

set 

 

 
 
 

Содержание TT-157 E

Страница 1: ...1 Pump 10 7 2 Heating 10 8 Monitoring devices 10 8 1 Level control 10 8 2 Indication of faults audible alarm 10 9 Inspection and maintenance according to DIN 31051 11 9 1 Inspection 11 9 2 Maintenance...

Страница 2: ...optimizing microprocessor controller 9kw 3 6 9kw lime free thermostat 2 Technical data 90 150 self optimizing microprocessor controller MP 694 C 3 6 9 kw 3 kW 0 75 kw max 4 0 bar max 75 l min max 8 m...

Страница 3: ...Manual TT 157 E 3 3 Safety and use as agreed 9kw 3kw 5 TT 157 E EN 1050 DIN 4844...

Страница 4: ...Manual TT 157 E 4 DANGER IP 44 9kw 3kw 4 Installation...

Страница 5: ...Manual TT 157 E 5 4 1 Fluid connections R 1 2 13 mm R 3 8 10 mm R 3 8 10 bar Quick 4 2 Power supply phases L1 L2 L3 earth PE max 10 1 kW...

Страница 6: ...Manual TT 157 E 6 4 3 Filling 6 litres see chapter 15 SEE CHAPTER 15 20 4 4 Pump rotation check 2...

Страница 7: ...5 Heat transfer liquid 9kw 3kw see point 6 4 and change over instructions in chapter 15 5 1 Water 9kw WTF 3 9kw 5 2 Heat transfer oil 3kw BP Transcal N Mobitherm 605 Shell Thermia Oil B TOOL TEMP WTF...

Страница 8: ...Manual TT 157 E 8 6 Operations 6 1 Setting of the temperature MP 694 C see chapter 13 6 2 Leak prevention operation VAC 13 mm Quick Quick...

Страница 9: ...Manual TT 157 E 9 6 3 Automatic mould drainage ON OFF VAC 4 5 1 5 6 4 Change over of the heating power 9kw 3 kw chapter 15 CHAPTER 15...

Страница 10: ...157 E 10 7 Safety devices 7 1 Pump relay 7 2 Heating 150 150 MP 694 C thermostat 155 140 thermostat 95 8 Monitoring devices 8 1 Level control 8 2 Indication of faults audible alarm off overload relay...

Страница 11: ...11 9 Inspection and maintenance according to DIN 31051 9 1 Inspection TT 157E 9 2 Maintenance 1 6 1 6 4 000 These intervals are for standard operation For extreme service these intervals must be short...

Страница 12: ...probable cause Correction transformer relay 5 20 mm 1A Unit off ON OFF Controller off relay 2 phase overload relay Unit off ON OFF Controller off thermostat thermostat off float Heating off see Progra...

Страница 13: ...3 11 Control panel TOOL TEMP AG CH 8583 Sulgen Switzerland TT 157 E serial number Volt Watt Hz sign CE I 1 3 kW 3 kW II 2 6 kW 3 kW I and II 9 kW 3 kW VAC ON OFF ON OFF on off VAC approx 5 sec see Pro...

Страница 14: ...Manual TT 157 E 14 12 Views and dimensions mm 12 1 Back view 70 OUT 1 2 OUT R 3 8 IN R 3 8 overflow 175 100 165 230 600 IN R1 2 55 600 530 375 330 70 12 3 connecting dimensions 12 2 Front view...

Страница 15: ...Manual TT 157 E 15 12 4 Inside view by pass Float Float R 1 4 R 1 4 R 3 8 Box IN thermostat 3 3 kW controller...

Страница 16: ...Manual TT 157 E 16 12 5 Inside view switch cabinet thermostat F10 MP 694 Controller N1 2 F8 S 7 H15 contactor K1 F7 contactor K3 K4 3kW or 9kW relay F1 T1 S10...

Страница 17: ...Manual TT 157 E 17 signal of 0 10 V or 4 20 mA 5 key Kep P 4 P1 0 400 C P2 20 C 5 C set point 0 10 V or 4 20 mA ON ON Type...

Страница 18: ...Temperature with 5 V analogue out 0 400 200 PG 32 Actuator analogue out analogue P31 P32 0 0 PG 33 pos actuator 0 5 V 1 actuator 2 5V 2 Limit time 100 200 s 60 s PG 38 Upper l limit 0 5 5 0 0 5 PG 39...

Страница 19: ...h Gk0200000 VAC switch for leakstopper device with 2 switching levels complete only for TT 155 and 156 E Gk0200100 VAC switch with 3 switching levels complete front and back part Gk0200200 VAC switch...

Страница 20: ...mpeller 50 Hz 71 mm 8 Impeller 60 Hz 68 5 mm 9 Pump body 10 Terminal board 11 Terminal box 12 Screw type conduit fitting 13 Shaft sealing ring 14 Splash ring 15 Splash ring 16 Splash ring 17 Flange bu...

Страница 21: ...stadi riscaldamento Stufenschaltung Change of stages Changer tages de chauffe Cambio potenza di riscaldamento 1 2 3 4 7 8 8 9 9 10 14 E E Klemmen terminals borniers attacchi Heizungsschalter Switch f...

Страница 22: ...Elettrovalvola riempimento autom 8 Kugelventil f r Wasserbetrieb Ball valve for work with water Robinet pour op ration eau Valvola manuale per funzionamento ad acqua 15 Schwimmer Float Flotteur Galleg...

Страница 23: ...Manual TT 157 E 23...

Страница 24: ...Manual TT 157 E 24...

Страница 25: ...Manual TT 157 E 25...