WARNING
CAUTION
CAUTION
��
2-1 Safety measures
2.1.1 Handling of this product
This product should be handled by knowledgeable and experienced technicians only.
Compressed air, etc. is hazardous if wrongly handled. Assembly, operation, maintenance of a machine
or a unit utilizing compressed air should be handled by technicians who have read the instruction
manual (hereinafter "this manual") thoroughly and understand the contents completely.
2.1.2 Safety check
Handling or dismantling of the machine or the unit must not be carried out until safety
precautions are ensured.
The machine should only be dismantled after checking the following items to ensure safety.
①
Safety precautions for this product, such as preventions against falling of parts, material or other
accidental happenings, have been taken.
②
The surface temperature of this product is a temperature where the surface can be touched.
③
Supply air, etc. that are power sources and compressed air in the air piping system have been
removed.
④
No fluid flows in the pipelines.
⑤
The power of the system has been shut off.
Before restarting of the unit, check the following items.
①
This product is fixed to a valve securely.
②
There is no failure or damage on the appearance of this product, or loss of parts.
③
Tools have not been left on this product.
④
Nothing hinders operation of this product (operation of the cylinder, opening/closing of the valve).
⑤
There is no leakage of electrical and pneumatic signals.
⑥
There is no leakage of compressed air, etc.
2.1.3 Fail-safe design
When the unit is used for the point where fail-safe design is required, adopt a method where the
system responds in a way that will cause no harm using a single-acting type cylinder (spring back
cylinder), a lock-up valve, etc. in case of loss of all or a part of power that controls the machine.
2.1.4 Water hammer
Design should be performed in consideration of water hammer. Water hammer may occur even
within the opening and closing times in the range of the product specifications, depending on the
pipeline conditions or valve operating conditions.
2-2 Transportation and storage
2.2.1 Mass
Products with large mass (approx. 20 kg) should be transported using equipment or a machine, not
by man power alone. See the catalog issued by our company, product drawings, etc. for the mass
of this product. Qualified personnel should perform work with a forklift or a crane, or slinging work in
accordance with laws and regulations, and safety provisions of business establishments.
2.2.2 Falling
When this product is unloaded or transversely held, it should be held appropriately to prevent it from
falling and being damaged.
2.2.3 Dust-proofing, water-proofing
The plug (tentative seal plug) connected to the piping connection should not be removed until
pneumatic piping work is performed. If dust-proofing and water-proofing measures are not taken,
dirt, dust, rainwater, etc. will infiltrate this product, causing defective operation. If the plug is lost,
take protective measures using a cover or protection tape instead. For single-acting type cylinders,
orient the elbow of the exhaust port downwards to prevent infiltration of dirt, dust, rainwater, etc.
2. PRECAUTIONS FOR USE
3
4
Type
Torque (N·m)
(When supply pressure
is 0.4MPa and
rotation angle is 0°)
Supply air pressure
condition/temperature
Air supply
pressure (MPa)
Body shell max (MPa)
Air connection (Rc)
Rotating angle
Ambient temperature
Travel time (sec)
With speed controller *
Dehumidified air / -10°C ~ +60°C
0.4 ~ 0.7MPa
1.05MPa
Rc (PT)1/4
90°
-10°C ~ +60°C
T35
35
T85
85
T200
200
T380
380
T750
750
T85S
30
T200S
65
T380S
116
T750S
240
1~15
2~15
3~15
7~20
12~25
2~15
6~15
8~20
15~25
Double-acting type cylinder (7E)
Single-acting type cylinder(7F/7G)
1-3 Type description
1-4 Standard specifications
Double-acting type cylinder (7E) Single-acting type cylinder (7F/7G)
T85
① ②
T 8 5 S
① ② ③
* The output torque of single-acting type differs from that of double-acting type. Please refer to 1-4 Standard
specifications.
* The opening and closing times are the times in the case of a single unit of a cylinder with a standard speed
controller (SP-K017-Z03-006) and a solenoid valve (PCS2408-NB-100MC) when the air supply pressure is 0.4
MPa.
The opening and closing times depend on pneumatic piping system, etc.
①
Identification of this product
②
Identification of type
③
Operation type: Spring return
①
Identification of this product
②
Output torque (*)