4-4 Manual operation procedure

When setting the position to open or close on this product 

manually, follow the procedures below.

(1) Preparation before manual operation

When the bypass valve (option) is not installed

 Remove the solenoid valve or the air pipeline of this 

product and equalize the air pressure in both the left and 

right cylinder chambers for the piston.

When the bypass valve (option) is installed

 Loosen the cross-recessed head screw on the bypass 

valve. [Fig. 5] 

 Pull out the knob fully. [Fig. 6]

 Once the knob is pulled out fully, the bypass valve will 

open and the pressure in both the left and right cylinder 

chambers for the piston will equalize.

(2) Manual operation procedure

When the manual gear and the manual screw handle are 

not installed

When the manual gear (option of double-acting type 

cylinder) is installed

 Operate the clutch in accordance with the instructions on 

the nameplate on the gear, and turn the handwheel to 

open and close the valve. [Fig. 8] 

 After operation, always return the clutch to the automatic 

position setting.

When the manual screw handle (option of single-acting 

type cylinder) is installed

 Loosen the hexagon nut and the hexagon bolt located at 

the base of the handle shaft. [Fig. 9] 

 Turn the handwheel in accordance with the direction 

indicated on the nameplate located in the middle of the 

manual screw handle to open and close the valve. [Fig. 9]

(3) Recovery after completion of manual operation

When the bypass valve is installed

 Push in the knob all the way, and tighten the cross-

recessed head screw to lock the knob.

 Reconnect the solenoid valve or the air pipeline.

When the manual gear and the manual screw handle are 

not installed

 Remove spanner, monkey wrench, or special lever.

 Reconnect the solenoid valve or the air pipeline.

When the manual gear (option of double-acting type 

cylinder) is installed

 After operation, always return the clutch to the automatic 

position setting.

 Reconnect the solenoid valve or the air pipeline.

When the manual screw handle (option of single-acting 

type cylinder) is installed

 After manual operation, always turn the handwheel all the 

way in the reverse direction of manual operation until the 

handle shaft is at its shortest possible position. [Fig. 9] 

 After returning the handle shaft to its shortest possible 

position, tighten the hexagon nut and the hexagon bolt to 

fix the handwheel.

 Reconnect the solenoid valve or the air pipeline.

[Fig. 5]

[Fig. 6]

Cross-recessed head screw

Knob

[Fig. 8]

[Fig. 9] 

Clutch

Nameplate

Hexagon bolt

Hexagon nut

Approx. 10 mm

Automatic operation 

(Bypass valve closed)

Manual operation

(Bypass valve open)

• Do not use a spanner, a monkey wrench, or the 

special lever in the following cases as it could result in 

a dangerous situation.

(1)  For single-acting type cylinders, do not set the 

position to open or close manually using a spanner, 

a monkey wrench, or the special lever. Otherwise, 

the spanner, the monkey wrench, or the special 

lever is pushed back by the spring force, which may 

cause injury. Use a manual screw handle.

(2)  For T750, since the operating force is large and 

therefore dangerous, do not perform external 

manual operation using a spanner or a monkey 

wrench. Use a manual gear.

•  Depending on the type of accessories, the special 

lever may not be usable.

[Fig. 7]

 As the center axis of this product is width across flat, use a 

spanner, a monkey wrench, or the special lever to set the 

position to open or close on this product.

Rotate the knob and pull it out all 

the way with approx. 10 mm of 

stroke.

CAUTION

Содержание T-DYNAMO 7E

Страница 1: ...pe cylinder 3 2 Expanded view Single acting type cylinder 3 3 Output torque curves 3 4 Air consumption 4 CYLINDER SYSTEM CONFIGURATION 4 1 System configuration 4 2 Speed controller 4 3 Adjustment of v...

Страница 2: ...and inspection of this product If there are any questions please contact our sales department Reference values and limit values for operation maintenance and inspection specified in this instruction...

Страница 3: ...packing 2 The shaft penetrates the chamber of the case The yoke is fitted in the hole across the shaft in such a way that it allows it to slide in the hole The top of the yoke is connected with the p...

Страница 4: ...ting type cylinder 7F 7G 1 3 Type description 1 4 Standard specifications Double acting type cylinder 7E Single acting type cylinder 7F 7G T85 T 8 5 S The output torque of single acting type differs f...

Страница 5: ...2 1 3 Fail safe design When the unit is used for the point where fail safe design is required adopt a method where the system responds in a way that will cause no harm using a single acting type cylin...

Страница 6: ...ocation The following measures should be taken depending on the atmosphere of the location where this product is installed Locations which are exposed to gas containing salt corrosive gas chemical sol...

Страница 7: ...le paying attention to the following items If dents or scratches are made on impact to ensure safety stop using the product and replace the product This product attachments and pneumatic pipelines sho...

Страница 8: ...atic devices in which the pneumatic pipeline inlet of this product or the end of the plant pipeline is connected with a long pipeline air supply amount and air supply pressure may be insufficient for...

Страница 9: ...ion check that the manual gear is at the position of automatic operation and the bypass valve is closed They are not returned automatically 2 4 8 Others If air supply is stopped for a long period of t...

Страница 10: ...be checked that opening of the valve and the opening of this product are the same If the openings are not the same opening and closing operation is performed in the reverse way 2 5 6 Replacement of c...

Страница 11: ...ng washer cover 1 2 8 14 Bearing 2 1 T35 only 47 Hexagon socket head cap screw cover 1 2 8 15 Bearing 3 lower shaft 1 49 Hexagon socket head cap screw base plate 4 T35 2pcs 16 Bearing 4 upper shaft 1...

Страница 12: ...2 1 37 Stopper bolt 1 T750S only 8 Base plate 1 42 Spring 2 9 Bearing 2 43 Spring guide 2 11 Indicator plate 1 44 Hexagon bolt spring guide 2 13 Bearing 1 shaft piston 2 45 Spring washer spring guide...

Страница 13: ...e cylinder air consumption N VS Single acting type cylinder air consumption N A B Cylinder capacity P Operating pressure MPa N Operating frequencies in a given time 1 round trip 1 CD Double acting typ...

Страница 14: ...box This switch box is for remotely displaying the open close status of the valve Positioner unit E P Positioner and P P Positioner This unit features a function that allows total control of the valve...

Страница 15: ...ht knob and adjust the closing speed with the left knob For single acting type cylinders only the speed when operating air is discharged can be adjusted Adjust the speed only with the right knob For p...

Страница 16: ...sition becomes shallow Please refer to Table 1 for rotation angles Hexagon stop screw Hexagon stop screw Seal washer Position indicator For pressure closing single acting type cylinders 7F the opening...

Страница 17: ...red angle The hexagon stop screw is rotated clockwise and the valve full open position becomes shallow Please refer to Table 1 for rotation angles How to restore after adjustment 1 Hold the hexagon st...

Страница 18: ...w Knob Approx 10 mm Automatic operation Bypass valve closed Manual operation Bypass valve open Do not use a spanner a monkey wrench or the special lever in the following cases as it could result in a...

Страница 19: ...en the cross recessed head screw to lock the knob Reconnect the solenoid valve or the air pipeline When the manual gear and the manual screw handle are not installed Remove spanner monkey wrench or sp...

Страница 20: ...h the attachment part plate and the filter regulator with the attachment part clamp 3 Fasten the attachment part clamp with screws long Fig 12 Installation procedure P31EA22MMBNNP Rc1 4 0 4 0 7MPa Max...

Страница 21: ...ed on cover 1 of this product Fig 13 2 The solenoid valve installation orientation depends on whether the valve is opened or closed when energized To reverse the orientation remove the solenoid valve...

Страница 22: ...ous situation 1 Set the position to full close on this product 2 Loosen the cover holding bolts at the four corners of the limit switch box and remove the top cover Fig 15 3 Pull the top cover out upw...

Страница 23: ...tic pipelines and electric wiring from this product 2 Remove the bolts and spring washers that fasten this product to the valve then take out this product from the valve Removal of the unit from the v...

Страница 24: ...1 Q ty 2 pcs for each 4 pcs for each Type 35 T85 T750 T85S T750S 7 Take out the yoke and the bearing from the case Please note that the type and quantity of the bearing of T35 is different from those...

Страница 25: ...screw in the bolts to the length shown in Table 8 and tighten them Fig 23 Not required for T750S 7 Loosen the hexagon socket head cap screws and alternately When the cover and the bolts for disassem...

Страница 26: ...is a mounting direction for the yoke Assemble the unit so that the face stamped with UP mark of the yoke faces to the upper side of the cylinder Note If F mark is stamped on the yoke instead of UP ma...

Страница 27: ...sure the free movement of the piston Fig 33 Insert the connecting pin after making sure that the pin hole of the yoke and the pin hole of the shaft are aligned Insert the connecting pin into the tappe...

Страница 28: ...le 12 Grease application amount Thrust plate Case Stopper Shaft Thrust plate Base plate Hexagon socket head cap screws Spring washer For T35 Apply liquid gasket to the designated area on the base plat...

Страница 29: ...t wrong cover installation causes defective operation such as air leakage Forcible assembly of single acting type cylinders such as uneven tightening of the hexagon socket head cap screw to mount the...

Страница 30: ...hten the bolts for disassembly until the dimension A in the figure becomes the distance where the hexagon socket head cap screws which had been mounted to the product can engage the case And then inst...

Страница 31: ...e knob of the speed controller Supply pressure of compressed air etc is high Decrease the air supply pressure within the range of the specifications of this product Speed controller is closed too much...

Страница 32: ...aused by fire flood earthquakes fall of rocks and other acts of God 12 The failure was caused by other reasons which are not our responsibility In addition the forgoing warranty is only applicable to...

Отзывы: