ZT-1 User’s Manual – Installation
DOC #18172 Page 21
TRK/PEAK switch setting on the front panel.
•
REV_C terminal outputs the reverse peak (snap-through) tonnage when the front
panel TRK/PEAK switch is set to PEAK.
•
TRK_C terminal always outputs the track tonnage, regardless of the front panel
TRK/PEAK switch.
Triggering – Internal Threshold
The ZT-1 can be triggered by an internal threshold value. When this triggering method is
used, the ZT-1 begins monitoring when the load rises above the level determined by the
front panel’s
Th.H / L
switch. Refer to Figure 10 below to configure the ZT-1 for threshold
triggering.
Содержание ZT-1
Страница 1: ...ZT 1 Load Module User s Manual For Pre calibrated Load Cells or other Load Cell use Revision A...
Страница 2: ...ZT 1 User s Manual Installation DOC 18172 Page 2...
Страница 3: ...ZT 1 User s Manual Installation DOC 18172 Page 3 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 7: ...ZT 1 User s Manual Installation DOC 18172 Page 7 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 9: ...ZT 1 User s Manual Installation DOC 18172 Page 9 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 14: ...ZT 1 User s Manual Installation DOC 18172 Page 14 Figure 4 Strain Gage Sensor Input...
Страница 18: ...ZT 1 User s Manual Installation DOC 18172 Page 18 Figure 7 20mA out Sensor Input...
Страница 33: ...ZT 1 User s Manual Operation DOC 18172 Page 33 3 Set the OFF PRB switch to PRB...
Страница 34: ...ZT 1 User s Manual Operation DOC 18172 Page 34...
Страница 36: ...ZT 1 User s Manual Appendix DOC 18172 Page 36 THIS PAGE INTENTIONALLY LEFT BLANK...