DC Power Connection (DC unit only)
DC power is connected to the PWi Forging’s Analog Board as shown in Figure 1.6. The external
24VDC power supply should be rated at 1.25A or higher. Use Conduit Hole #3 (see Figure 1.4)
for the DC Power Wiring. Use the proper fuse as indicated. If the power cable has a shield, it can
be connected to the Chassis Ground terminal.
DC Power Connection
24V DC
DC COM
CHASSIS GND
Fuse: Type TR5
Slow-Blow
1.25A
Figure 1.6: DC Power Connection