PWi Forging User’s Manual
Doc #17663 Rev A Page
Toledo Integrated Systems
17
Sensor Cable Termination
1)
Strip the sensor cable as shown in the figure below. Be sure not to nick any of the signal
conductors or cut the braid shield.
Figure 1.9: Sensor Cable Stripping
2)
Strip approximately ¼" of insulation from each of the four signal conductors.
3)
Trim braid shield so that it is ¼" to ½" shorter than the signal wires.
Note:
If your sensor cable is not double shielded with both foil and a braid, electrical noise may
affect your output readings.