In the event that a fault condition does exist, the fault code will be
displayed (matching the fault code flashing on the unit’s LED) and a
button labeled “Description” will appear. When pressed it will
provide a brief description of the fault in question, whether the fault
is “Fatal” (cycle power required) or “Non-fatal” and in some cases,
how the fault may be cleared.
OSCILLOSCOPE
The built-in virtual oscilloscope in the Tol-O-Motion Axiom setup
and tuning software is designed specifically for Axiom Plus tuning.
The oscilloscope is controlled by four buttons, located on the center
of the section:
Enable
- Sets the scope to trigger on the next event.
Trigger
- Brings up the trigger menu.
Clear
- Clears the screen of the last event snapshot.
Slider
- Enables/disables the slider feature. The slider allows
accurate readings of the traces.
Display Selections
This area has four choices: Position Error, Torque, Acceleration and
Velocity. Boxes checked will be displayed graphically on the scope.
Clicking on a selection (ie. Position Error) will cause the scope
window and slider to be scaled for optimal display of that particular
parameter. The “scaled” parameter is indicated by a box outlining
the word. You can then read that parameter’s value at any point
along the graph by moving the slider.
Scaling and Values/Units
All units are automatically scaled and displayed in the boxes in this
section. The bottom two boxes display the X and Y coordinates that
correspond to the Slider bar position.
Oscilloscope Settings
To take a reading, you must first define the Oscilloscope settings.
Note: If the Oscilloscope Settings menu is not visible, press the Clear
button.
•
Sweep Time
– This value can be set from .02 seconds to 20
seconds. This is the time period for one complete display sweep.
11 -3
F I N A L
C H E C K O U T
& T U N I N G : 1 1