Use the following procedures to remove components. Use the same procedures in reverse to
reassemble.
(Installation, inspection, maintenance, repairs, disassembly, adjustment and valve
opening/closing should be carried out only by trained maintenance personnel.)
NOTE: This section explains disassembling and reassembling of the bimetal unit only. For other
parts, refer to page 10 to page 11.
9.2 Disassembly/Reassembly
CAUTION
When disassembling or removing the product, wait until the internal
pressure equals atmospheric pressure and the surface of the product
has cooled to room temperature. Disassembling or removing the product
when it is hot or under pressure may lead to discharge of fluids, causing
burns, other injuries or damage.
WARNING
NEVER apply direct heat to the float. The float may explode due to
increased internal pressure, causing accidents leading to serious injury or
damage to property and equipment.
CAUTION
Use hoisting equipment for heavy objects (weighing approximately 20 kg
(44 lb) or more). Failure to do so may result in back strain or other injury if
the object should fall.
Disassembly/Reassembly of the Bimetal Section
Reassembly
Part
Disassembly
Element Cover
Consult the table of
tightening torques and
tighten to the proper
torque
Remove with a
socket wrench
Element Cover
Gasket
Replace with a new
gasket
Remove the gasket
and clean sealing
surfaces
Spring Clip
Insert it securely into
the groove
Pinch the insides
together and
remove from the
element guide
Bimetal Unit
Insert the bimetal unit
into the element guide
with "T" mark on the
bimetal facing towards
the air vent valve seat.
-
Air Vent Valve
Seat
(for Bimetal)
Consult the table of
tightening torques and
tighten to the proper
torque
Remove with a
socket wrench
Spring Clip
Bimetal Unit
Air Vent Valve
Seat
Element Guide
English
̶ 15 ̶