A
D
H
F
C
B
E
B
I
C
G
E
H
J
D
A
F
CAUTION
The pressure and temperature values displayed on the nameplate of
the connector body are the values for the connector body itself and
not for the entire trap.
Improper use may result in such hazards as damage to the product or
malfunctions that may lead to serious accidents.
DO NOT disassemble or remove this product or use the scale
removal function while it is under pressure.
Allow internal pressure of
this product to equal atmospheric pressure and its surface to cool to
room temperature before disassembling, removing or using the scale
removal feature. Failing to do so could cause burns or other injury.
Be sure to use only the recommended components when repairing
the product, and NEVER attempt to modify the product in any way.
Failure to observe these precautions may result in damage to the product
or burns or other injury due to malfunction or the discharge of fluids.
Use under conditions in which no water hammer will occur.
The
impact of water hammer may damage the product, leading to fluid
discharge, which may cause burns or other injury.
Use only under conditions in which no freeze-up will occur.
Freezing
may damage the product, leading to fluid discharge, which may cause
burns or other injury.
2. Specifications
* Maximum allowable pressure (PMA) and maximum allowable temperature (TMA) are
PRESSURE SHELL DESIGN CONDITIONS,
NOT
OPERATING CONDITIONS.
** Valve No. is displayed for products with options. This item is omitted from the nameplate
when there are no options.
*** Set pressure and set temperature are the initial settings when shipped from the factory.
Refer to the product nameplate on the trap unit for detailed specifications.
A nameplate is also mounted on the F46 connector unit. The specifications displayed on the
nameplate are the values for the connector body itself. When a trap unit is installed, the
PMA/TMA and PMO/TMO are limited to the trap unit specifications.
To avoid malfunctions, product damage, accidents or serious injury,
install properly and DO NOT use this product outside the specification
range. Local regulations may restrict the use of this product to below the
conditions quoted.
CAUTION
A: Model
B: Nominal Diameter
C: Max. Allowable Press.*
D: Max. Allowable Temp.* (TMA)
E: Max. Operating Press.
F : Max. Operating Temp. (TMO)
G: Valve No.**
H: Production Lot No.
I : Set Pressure***
J : Set Temperature***
Trap Unit
Connector Unit (mounted only on F46)
̶ 2 ̶