background image

14

.          Express Limited Warranty

Subject to the limitations set forth below, TLV Corporation, a North Carolina corporation (“

TLV

”) 

warrants that products which are sold by it or TLV International, Inc., a Japanese corporation 
(“

TII

”), which products (the “

Products

”) are designed and manufactured by TLV Co., Ltd., a 

Japanese corporation (“

TLVJ

”), conform to the specifications published by TLV for the 

corresponding part numbers (the “

Specifications

”) and are free from defective workmanship 

and materials. With regard to products or components manufactured by unrelated third parties 
(the “

Components

”), TLV provides no warranty other than the warranty from the third party 

manufacturer(s).

Duration Of Warranty

This warranty is effective for a period of the earlier of: ( i ) three (3) years after delivery of Products 
to the first end user in the case of sealed SST-Series Products for use in steam pressure service 
up to 650 psig; (ii) two (2) years after delivery of Products to the first end user in the case of 
PowerTrap

®

 units; or (iii) one (1) year afterdelivery of Products to the first end user in the case of 

all other Products. Notwithstanding the foregoing, asserting a claim under this warranty must be 
brought by the earlier of one of the foregoing periods, as applicable, or within five (5) years after 
the date of delivery to the initial buyer if not sold initially to the first end user.

ANY IMPLIED WARRANTIES NOT NEGATED HEREBY WHICH MAY ARISE BY OPERATION OF 
LAW, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A 
PARTICULAR PURPOSE AND ANY EXPRESS WARRANTIES NOT NEGATED HEREBY, ARE 
GIVEN SOLELY TO THE INITIAL BUYER AND ARE LIMITED IN DURATION TO ONE (1) YEAR
FROM THE DATE OF SHIPMENT BY TLV.

Exclusive Remedy

THE EXCLUSIVE REMEDY UNDER THIS WARRANTY, UNDER ANY EXPRESS WARRANTY OR 
UNDER ANY IMPLIED WARRANTIES NOT NEGATED HEREBY (INCLUDING THE IMPLIED 
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE), IS 

REPLACEMENT

; PROVIDED: (a) THE CLAIMED DEFECT IS REPORTED TO TLV IN WRITING 

WITHIN THE APPLICABLE WARRANTY PERIOD, INCLUDING A DETAILED WRITTEN 
DESCRIPTION OF THE CLAIMED DEFECT AND HOW AND WHEN THE CLAIMED DEFECTIVE 
PRODUCT WAS USED; AND (b) THE CLAIMED DEFECTIVE PRODUCT AND A COPY OF THE 
PURCHASE INVOICE IS RETURNED TO TLV, FREIGHT AND TRANSPORTATION COSTS 
PREPAID, UNDER A RETURN MATERIAL AUTHORIZATION AND TRACKING NUMBER ISSUED 
BY TLV. ALL LABOR COSTS, SHIPPING COSTS, AND TRANSPORTATION COSTS 
ASSOCIATED WITH THE RETURN OR REPLACEMENT OF THE CLAIMED DEFECTIVE 
PRODUCT ARE SOLELY THE RESPONSIBILITY OF BUYER OR THE FIRST END USER. TLV 
RESERVES THE RIGHT TO INSPECT ON THE FIRST END USER'S SITE ANY PRODUCTS 

Exceptions To Warranty

This warranty does not cover defects or failures caused by:

1. improper shipping, installation, use, handling, etc., by other than TLV or service 

representatives authorized by TLV; or

2. dirt, scale or rust, etc.; or
3. improper disassembly and reassembly, or inadequate inspection and maintenance by other 

than TLV or service representatives authorized by TLV; or

4. disasters or forces of nature; or
5. abuse, abnormal use, accidents or any other cause beyond the control of TLV; or
6. improper storage, maintenance or repair; or
7. operation of the Products not in accordance with instructions issued with the Products or 

with accepted industry practices; or

8. use for a purpose or in a manner for which the Products were not intended; or
9. use of the Products in a manner inconsistent with the Specifications; or

10. failure to follow the instructions contained in the TLV Instruction Manual for the Product.

Содержание QuickTrap FX1

Страница 1: ...al in a safe place for future reference F46 F32 Copyright C 2019 by TLV CO LTD All rights reserved 881 Nagasuna Noguchi Kakogawa Hyogo 675 8511 Japan Manufacturer Tel 81 0 79 422 1122 Fax 81 0 79 422 0112 Option BD2 UNIVERSAL TEMPERATURE CONTROL STEAM TRAP ...

Страница 2: ... designed to ensure safety and prevent equipment damage and personal injury For situations that may occur as a result of erroneous handling three different types of cautionary items are used to indicate the degree of urgency and the scale of potential damage and danger DANGER WARNING and CAUTION The three types of cautionary items above are very important for safety be sure to observe all of them ...

Страница 3: ...Use only under conditions in which no freeze up will occur Freezing may damage the product leading to fluid discharge which may cause burns or other injury 2 Specifications Maximum allowable pressure PMA and maximum allowable temperature TMA are PRESSURE SHELL DESIGN CONDITIONS NOT OPERATING CONDITIONS Valve No is displayed for products with options This item is omitted from the nameplate when the...

Страница 4: ...g Guide Thrust Plate Cap Nut Gasket Connector Flange Snap Ring R M T No 13 14 15 16 17 18 19 20 21 22 23 Description Outer Connector Gasket Inner Connector Gasket Connector Body Screen Screen Holder Gasket Screen Holder Connector Bolt Flange Nameplate Connector Unit Caution Plate A Caution Plate B R M T No 24 25 26 27 28 29 30 31 32 A B Replacement parts for F32 differ from those for F46 When orde...

Страница 5: ... or using 13 12 16 21 24 30 27 28 29 26 25 22 15 17 20 10 11 19 14 2 3 6 6 9 7 8 5 4 32 18 Cover Unit Valve Unit Cover Unit Valve Unit The X1 trap unit is designed for use with TLV F46 and F32 connector units and TLV V1 V2 V1P V2P Series trap stations It is not compatible with TLV F46J connector unit The connector unit name is indicated on the connector body Trap Unit X1 Connector Body Unit F46 or...

Страница 6: ...ide of the trap 7 Install in a place where caution plates including cap can clearly be seen during periods of maintenance in the lowest part of the pipeline so that condensate flows into the trap by gravity 8 Install inlet and outlet valves to isolate the product in event of trap failure or maintenance 9 If the product is subject to back pressure install a check valve 10 Open the inlet valve gradu...

Страница 7: ...o room temperature Do not remove the cap nut unless the trap is isolated from and is not subjected to steam pressure 2 Hold the cover with one wrench and use another wrench to slowly loosen and remove the cap nut Remove cap nut slowly to allow any residual pressurized steam to leak from the trap interior through the threads of the adjustment screw and the cover 3 Hold the adjusting screw in place ...

Страница 8: ...barg 212 F at 130 psig 1 MPa 10 197 kg cm2 10 bar Adjusting Screw Adjuster Slot Cover A B Standard Factory Setting 0 Position The standard 0 position is the position where point A the bottom of the adjusting screw slot is even with point B the top surface of the cap FX1 100 C at 0 9 MPaG 9 barg 212 F at 130 psig Temperature Setting Range 1 MPa 10 197 kg cm2 10 bar Set Temperature F Operating press...

Страница 9: ...e steam is safely turned on using the instructions that follow 7 Replace the cap nut and tighten it to the proper torque see page 10 8 First fully open the outlet isolation valve and then slowly and carefully open the inlet isolation valve checking for any steam leaks In the event steam leaks are detected immediately close the inlet isolation valve then the outlet isolation valve and repair the so...

Страница 10: ... valve stem Washer 5 sets 6 Remove the bimetal element from the valve stem by lifting up and off Reassemble the bimetal elements paying special attention to the proper orientation the TLV marks on the outside see Exploded View p 4 Bimetal Element 5 sets of 2 discs 5 Cap Nut Gasket 21 Part No Connector Bolt See separate instruction 10 1 See separate instruction 10 1 Connector Gaskets Gasket s Seal ...

Страница 11: ...rap unit from the connector body and take it to a repair area where it can be supported in a vise during disassembly 2 A When reinstalling the original trap a Using a small screwdriver remove the old gaskets from their housings in the trap body then clean the housings b New connector gaskets must be installed c To facilitate assembly and prevent loosening of the gaskets apply a small amount of sui...

Страница 12: ...kit The seal on the threaded plugs holders found on TLV products is formed by a flat metal gasket There are various installation orientations for the gaskets such as horizontal diagonal and downward and the gasket may be pinched in the thread recesses during assembly Instructions for Disassembly and Reassembly Remove the plug holder using a tool of the specified size distance across flats The gask...

Страница 13: ...uid discharge causing burns 1 With two wrenches firmly hold the BD2 valve seat screen holder 22 mm in place while slowly opening the BD2 valve 17 mm Be careful to avoid contact with fluid that will be discharged through the hole in the center of the blowdown valve as the valve opens 2 Close the BD2 valve and tighten to a torque of 30 N m 22 lbf ft and confirm that there is no leakage If leakage co...

Страница 14: ...F SHIPMENT BY TLV Exclusive Remedy THE EXCLUSIVE REMEDY UNDER THIS WARRANTY UNDER ANY EXPRESS WARRANTY OR UNDER ANY IMPLIED WARRANTIES NOT NEGATED HEREBY INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IS REPLACEMENT PROVIDED a THE CLAIMED DEFECT IS REPORTED TO TLV IN WRITING WITHIN THE APPLICABLE WARRANTY PERIOD INCLUDING A DETAILED WRITTEN DESCRIPTION OF ...

Страница 15: ...IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE CANNOT BE EXCLUDED SUCH DAMAGES ARE EXPRESSLY LIMITED IN AMOUNT TO THE PURCHASE PRICE OF THE DEFECTIVE PRODUCT THIS EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES AND THE PROVISION OF THIS WARRANTY LIMITING REMEDIES HEREUNDER TO REPLACEMENT ARE INDEPENDENT PROVISIONS AND ANY DETERMINATION THAT THE LIMITATION OF REMEDIES ...

Страница 16: ...Printed on recycled paper Tel 81 0 79 422 1122 Fax 81 0 79 422 0112 Rev 8 2019 M PAC 65502 a 881 Nagasuna Noguchi Kakogawa Hyogo 675 8511 Japan Manufacturer ...

Отзывы: