2. Specifications
To avoid malfunctions, product damage, accidents or serious injury,
install properly and DO NOT use this product outside the specification
range. Local regulations may restrict the use of this product to below the
conditions quoted.
CAUTION
Connector Unit (mounted only on F46)
A : Model
B : Nominal Diameter*
C: Max. Allowable Press.**
D: Max. Allowable Temp.**
E : Max. Differential Press.
F : Max. Operating Press.
G: Max. Operating Temp.
H: Valve No.***
I : Production Lot No.
* The nominal diameter is not printed on the trap unit nameplate when the trap unit is shipped by
itself.
** Maximum allowable pressure (PMA) and maximum allowable temperature (TMA) are
PRESSURE SHELL DESIGN CONDITIONS,
NOT
OPERATING CONDITIONS.
*** "Valve No." is displayed for products with options. This item is omitted from the nameplate
when there are no options.
Refer to the product nameplates on the trap unit AND on the connector body for detailed specifications. The
specifications displayed on each nameplate apply only to the unit on which it is mounted.
When the trap unit is installed on a connector unit and the PMA/TMA and/or PMO/TMO values displayed on
the two nameplates differ, the specifications for the assembled product are restricted to the lower values.
CAUTION
When disassembling or removing the product, wait until the internal
pressure equals atmospheric pressure and the surface of the
product has cooled to room temperature.
Disassembling or removing
the product when it is hot or under pressure may lead to discharge of
fluids, causing burns, other injuries or damage.
Be sure to use only the recommended components when repairing
the product, and NEVER attempt to modify the product in any way.
Failure to observe these precautions may result in damage to the product
or burns or other injury due to malfunction or the discharge of fluids.
Use only under conditions in which no freeze-up will occur.
Freezing
may damage the product, leading to fluid discharge, which may cause
burns or other injury.
Use under conditions in which no water hammer will occur.
The
impact of water hammer may damage the product, leading to fluid
discharge, which may cause burns or other injury.
The pressure and temperature values displayed on the nameplate of
the connector body are the values for the connector body itself and
not for the entire trap.
Improper use may result in such hazards as
damage to the product or malfunctions that may lead to serious accidents.
Trap Unit
A
C
G
H
E
D
I
A
D
I
C
G
B
F
̶ 2 ̶