172-65043MA-02 (GP10L/GT10L
PowerTrap
) 9 Mar 2004
24
1. Removing / Reattaching the Body from / to the Cover
Prepare a new, replacement cover gasket before beginning this step.
Part Disassembly Reassembly
Drain Plug
• Discharging condensate is carried out with intake
(motive medium), exhaust, inlet and outlet piping still
connected to the unit.
• Using a 300 mm (12") long adjustable wrench, slowly
loosen plug to release pressure and discharge fluid; take
care to avoid being burned by fluid discharge.
• Wrap threads with
3 – 3.5 turns of
sealing tape or apply
sealing compound.
• Tighten to a torque
of 30 N
⋅
m (22 ft
⋅
lb).
Cover Bolts
• Using a 24 mm (
15
⁄
16
") socket wrench, loosen each bolt
slowly one turn in an alternating diagonal pattern.
• Once all bolts have been loosened, verify that there is no
internal pressure before completely removing the bolts.
• Reverse steps in
disassembly.
• Tighten to a torque
of 110 N
⋅
m (81 ft
⋅
lb).
Anchors
• Remove the bolts that hold the anchor brackets to the
body and rotate the anchor brackets on their base bolts
so that they will not interfere with removal of the body
from the cover.
• Reverse steps in
disassembly.
Body / Cover • Make sure to secure sufficient space around the body to
allow it to be pulled straight off.
• As the body weighs approximately 28 kg (62 lb), use a
block and tackle hoist to assist in its removal.
• When moving the body away from and clear of the
cover, lift the body only about 1 cm (
3
⁄
8
"), to avoid contact
with the float and other internal parts.
• In addition, to avoid contact with the float when removing
the body, lift the float and the float lever slightly.
• Do not tilt the body more than 15° in any plane.
• Reverse steps in
disassembly while
referring to the
figure below.
Cover Gasket • The gasket will be destroyed upon disassembly,
adhering to both body and cover; using a scratch-free
scrapper, carefully scrape the gasket from both body
and cover surfaces.
• Check that all
pieces of old gasket
have been removed,
then install a new
gasket.
1 N
⋅
m
≈
10 kg
⋅
cm
2
Cover Gasket
Cover
Bolt
Body
Cover
Plugs for
Water Level
Gauge
Drain Plug
Motive Medium
Supply Pipe
Condensate Inlet Pipe
Condensate
Outlet Pipe
Exhaust Pipe
GP10L shown. GT10L
configuration differs slightly
Содержание PowerTrap GP10L
Страница 36: ......