172-65727MA-01 (CV-COS-16) 7 Oct 2021
21
Options
Install properly and DO NOT use this product outside the recommended
operating pressure, temperature and other specification ranges.
Improper use may result in such hazards as damage to the product or
malfunctions which may lead to serious accidents. Local regulations
may restrict the use of this product to below the conditions quoted.
CAUTION
Take measures to prevent people from coming into direct contact with
product outlets. Failure to do so may result in burns or other injury from
the discharge of fluids.
CAUTION
The following options are available to meet individual specification
requirements, so please verify your particular product.
Body Options (Section A) (Standard: No Plug)
No Plug
With Plug
(1 N·m ≈ 10 kg·cm)
Torque
Dist. Across Flats
N·m
(lbf·ft)
mm
(in)
30
(22)
12
(
1
/
2
)
NOTE: Wrap sealing tape 3
– 3.5 times
around the threaded portions.
Applications for Use
Where there are large amounts of dirt or scale, or for applications such as heating in
which the equipment is shut down for long periods of time, be sure to install a blow/
purge valve.
1. Remove the plug (optional) from the main body and install the blow/purge valve.
2. Open the blow/purge valve and blow any residual dirt and scale off of the screen.
3. Periodically activate the blow/purge valve to keep the system free of dirt and scale.
Rc(PT) 3/8
BSPT 3/8
NPT 3/8
A
B