172-65742MA-01 (CT20/CT20D) 7 Oct 2021
12
Detaching/Reattaching the Stem Connector Nut and Locknut
Part
During Disassembly
During Reassembly
Locknut,
Stem Connector
Nut
Loosen the locknut by holding the
stem connector nut with a
spanner
DO NOT disassemble with the
valve plug in contact with the valve
seat, make sure that the valve plug
is slightly suspended
Do not supply air to the actuator at
a pressure of 0.6 MPaG (85 psig, 6
barg) or more.
Consult the table of tightening
torques and tighten to the proper
torque
If the instructions given are not
followed when reassembly is
carried out, malfunctions such as
insufficient lift (insufficient flow
capacity) and/or insufficient closing
force (valve leakage) may result:
give the proper attention to the
adjustment procedure
Stem Connector Nut
Locknut