172-65116M-02 (CP-N) 16 Jun 2011
6
Installation
Install properly and DO NOT use this product outside the recommended
operating pressure, temperature and other specification ranges.
Improper use may result in such hazards as damage to the product or
malfunctions which may lead to serious accidents. Local regulations
may restrict the use of this product to below the conditions quoted.
CAUTION
Use hoisting equipment for heavy objects (weighing approximately
20 kg or more). Failure to do so may result in back strain or other injury if
the object should fall.
CAUTION
Make sure the power supply is OFF before carrying out work on the
wiring or inspections involving disassembly. If such work is carried out
with the power on, there is a danger that equipment may malfunction or
electric shock may occur, leading to injury or other accidents.
CAUTION
Make sure that wiring work requiring a special license is carried out only
by qualified personnel. If carried out by unqualified personnel,
overheating or short circuits leading to injury, fires, damage or other
accidents may occur.
CAUTION
Take measures to prevent people from coming into direct contact with
product outlets. Failure to do so may result in burns or other injury from
the discharge of fluids.
CAUTION
When using this product, NEVER stand close to, or leave tools anywhere
near, moving parts, such as the shaft. Contact with moving parts or
objects becoming caught in moving parts could lead to injury or
damage or other accidents.
CAUTION
Pump installation
Installation, inspection, maintenance, repairs, disassembly, adjustment and valve
opening/closing should be carried out only by trained maintenance personnel.
The preparation of the foundation and the installation of the pump and motor require
careful attention.
Incorrect installation and alignment would cause various troubles during operation. On
site, install the equipment correctly and check the alignment carefully as shown below,
although the equipment has been aligned before shipping.
1. Before installation, prepare packers and a set of shims (1 mm – 0.05 mm) for
adjustment.
2. When the foundation is completely solidified, in order to prevent the deformation of
the bed, determine the positions of the packers at both sides of the foundation bolt’s
seats, the pump legs, and motor legs. Put concrete and place the packers as
required.
In this case, the level of the packers should be checked using a spirit level. The level
of packers can be adjusted by the use of shims during installation.
3. When the concrete under the packers is solidified, place the bed, pump and motor
temporarily. Adjust the level axially and laterally by the use of shims while applying a
level.
4. When the position of the pump and the level are established, align the pump and
motor temporarily using an alignment tool.
5. After finishing the temporary alignment, fill the foundation bolt holes with concrete.