Configuration
The condensate recovery pump, CP-N consists primarily of a centrifugal or multi-stage
pump, ejector and delivery pressure regulating valve.
1. Centrifugal or multi-stage turbine pump
Pressurizes hot condensate and provides the motive power of ejector jet and pump
out force of condensate
2. Ejector
Mixes the pressurized condensate with the flow-in condensate, giving the required
(NPSH req) to the pump
3. Delivery pressure regulating valve
Maintains the pressure in the loop constant and pumps out condensate at a steady
pressure
4. Valve for air venting
Removes air in the piping and loop at startup