Operating instructions
24
As of 06/13
System stop time:
The
system stop time defines, how long no signal must be active,
until the projector gets switched off automatically. Herewith you can
prevent, that the projector will be switched off unnecessarily, if the
connected notebook during operation gets on stand-by and sends no
signal. If there is no signal at the system, the stop time begins.
Thereupon the yellow Info-LED lights up. If there is a signal again,
the yellow LED goes off and the timer will be reset.
Projector cool down time:
Cool down time is the time the projector lamp requires to cool down.
This period should be long enough to allow the projector to
completely cool off the lamp before switching off the mains supply.
The lamp may otherwise be damaged.
Projector safety time:
The safety time is the period required in case the projector has been
switched off without first cooling down the lamp. The lamp may be
damaged if the projector is switched back on immediately.
C 5.2.1.2.2 RS 232 Protocol
In this menu item the communication parameters of the display
device to be controlled can be set up. Please refer to the device
manual for the relevant data.