Switch Mounting
Compressor and Actuator switches should be mounted in a position best suited to the driver, consider the
following:
o
Switches must be hard mounted and never hanging from the wiring alone.
o
Switches should be easily seen and accessible to the driver.
o
Ensure that the switches are out of the way of accidental activation by passengers or driver.
o
Switches should be mounted away from potential exposure to water.
o
Enough room should be left behind the mounting face to fit the switch and wiring.
Note:
The Pro Locker actuator switches are supplied with the Pro Locker.
o
Create 21 mm x 41 mm rectangular cut-out
for each switch.
o
Securely snap switches into position.
o
When wired according to the wiring diagram
shown in Figure 1, the switch will illuminate
Green when the dash lights are ON, and Red
when the compressor is ON.
o
Alternatively, if Pro-Lockers are not used or
the compressor isolator switch is desired to
be installed elsewhere, a TJM Fascia Panel
(013COMPDFMK) may be used to mount the
compressor isolator switch.
o
Additionally, a standard 52mm Pressure
Gauge, 2x airbag Schrader valves and an
outlet port can also be installed on the panel.
o
It is suggested to mount the panel onto the
side fascia of the drawer system.