8
© Titan Tool. All rights reserved.
Tip change
changing the round spray tip
1. Screw out spray tip (B) with tip wrench (A). (See Fig.5)
2. Attach desired spray tip and tighten with tip wrench.
A
B
Figure 5
changing the round nozzle body
1. To remove the tip body (D) place the tip body removal tool
on the tip security lever (E), figure 6A. Squeeze and hold
as shown in figure 6B while unscrewing the tip body.
2. Screw out the spray tip (B) using the tip removal tool and
remove diffuser (C), figure 6C.
ImPORTaNT: carefully handle the carbide spray tip; avoid
cleaning with sharp-edged metal objects.
Figure 6A
Figure 6C
E
D
C
B
Air cap
Figure 6B
Tip removal tool
3. Reassemble in reverse order. Mount tip body (D) and
tighten by hand (do not use the tip removal tool).
4. When adjusting tip nut leave a gap for atomizing air
between the air cap and tip body.
Assembly of flat spray tip
If the round nozzle body is attached: Figure 7.
1. Remove tip body (D) from the spray gun body (F). Use
the procedure described in
changing the round nozzle
body.
Figure 7
Figure 8
G
F
H
J
D
F
2. Mount tip (G) on the paint channel of the spray gun body
(F). See figure 8.
3. Place spray gun body (H) on tip (G), fitting lugs of air cap
into grooves of tip insert.
4. Mount air cap (J) onto spray gun body until past the tip
security lever.
5. Adjust desired air jet level by means of air cap horns (J)
and tighten air cap.
all PaRTS NEEDED fOR ThE flaT TIP muST BE
PuRchaSED SEPaRaTEly. SEE PagE 18 fOR PaRT
NumBERS aND ORDERINg INfORmaTION.
Cleaning of the flat spray tip
1. Remove air cap (H), see figure 8.
2. Remove flat spray tip (G) and clean it.
3. Carefully handle the carbide flat spray tip (G); avoid
cleaning with a sharp-edged metal object.