TP 500 II
40
/
70
Fault
Cause
Remedy
The lower strap slips during
tension operation.
Distance between tension/feed
wheel and gripper plate (0.2 mm)
isn‟t correct.
Set the correct distance between
tension/feed wheel and gripper
plate, see 8.3.
Gripper plates are dirty or
defective.
Clean gripper plates or replace
them if they are defective, see 9.3
– 9.4.
Use of inappropriate plastic strap.
Use appropriate plastic strap, ask
your TITAN
– Adviser for advice.
Insufficient welding performance.
Welding time too short or too
long.
Set the correct welding time, see
8.1.
Gripper plate, welding
(24)
is dirty
or worn.
Clean gripper plate, welding
(24)
or replace it, see 9.4.
Welding time is hardly adjustable
and not constant.
Time valve in the compressed air
valve
(505)
dirty or defective.
Clean time valve in the
compressed air valve
(505)
and
lubricate or replace it, contact
TITAN
– Service.
Plastic strap welded incorrect,
sealing not O.K. Upper
strap isn‟t
completely cut and cutting isn‟t
constant.
Cutter
(21)
and gripper plate,
welding
(24)
are worn or
defective.
Replace cutter
(21)
and gripper
plate, welding
(24)
, see 9.1 and
9.4.
Welding time too short.
Check welding time and increase
it if necessary.
Welding motor
(501)
is dirty or
blocked.
When welding motor
(501)
is dirty
or blocked contact TITAN
–
Service.
Error in compressed air system.
Check constant air pressure and
repair it if necessary.
Compressed air valve
(505)
defective.
Check function of compressed air
valve
(505)
and contact TITAN
–
Service if it‟s defective.
Pressure spring
(20)
defective.
Replace pressure spring
(20)
.
Use of inappropriate plastic strap.
Use appropriate plastic strap, ask
your TITAN
– Adviser for advice.
During the welding operation both
straps are cutted.
Gripper plate
(78)
dirty or
defective.
Clean gripper plate
(78)
or
replace it when defective, see 9.3
– 9.4.
Tension force is too high.
Set the correct tension force, see
8.2.
Welding time too long.
Set the correct welding time, see
8.1.
After sealing and actuating push-
button 3
(66)
tension motor
(504)
will not turn back, strap isn‟t
released.
If the strap cannot be freed.
Cut off the strap from the
package and dismount the bottom
plate
(77)
, see 9.3 to reach the
problem zone.
Don’t use tools to
remove the stuck strap from
the tool.
Contact TITAN
–
Service.
Tension motor
(504)
dirty or
defective.
If tension motor
(504)
is dirty or
defective contact
TITAN
– Service.
Plastic strap holding unit is
defective.
Contact TITAN
– Service.
Compressed air valve defective
or error in the compressed air
system of the device.
Check function of the
compressed air valve and the
compressed air system of the
device on errors. Contact TITAN
– Service kontaktieren.
H TP 500 II EU 04/12
Содержание 0002
Страница 22: ...TP 500 II 22 70 11 Konformit tserkl rung H TP 500 II EU 44 11...
Страница 42: ...TP 500 II 42 70 11 Declaration of conformity of the machine H TP 500 II EU 44 11...
Страница 62: ...TP 500 II 62 70 11 D claration CE de conformit des machines H TP 500 II EU 44 11...
Страница 64: ...TP 500 II 64 70 12 Explosionszeichnungen Exploded drawings Vue clat e H TP 500 II EU 50 13...