9.3. Replacement of the gripper plate on the bottom plate
Remove the 6 fastening screws (Pos. 87) from the bottom plate (Pos. 77) (figure 9.3.1).
Afterwards remove the 5 screws (Pos. 86) (figure 9.3.2) and replace the required gripper
plates (Pos. 78 - 80) (figure 9.3.3).
Figure 9.3.1
Figure 9.3.2
Figure 9.3.3
Reassemble it in reverse order.
9.4. Replace gripper plate, welding
To replace the gripper plate of the welding unit
it‟s necessary to
remove the cutter and the
bottom plate first
, as described under point 9.1 + 9.3. Then remove the circlip (Pos. 26)
from the retaining bolt gripper plate (Pos.25) (figure 9.4.1) and pull the retaining bolt gripper
(Pos. 25) out of the gripper plate welding (figure 9.4.2) and replace it (figure 9.4.3).
Figure 9.4.1
Figure 9.4.2
Figure 9.4.3
Reassemble it in reverse order.
9.5. Cleaning work area
Remove the plastic
strap residues from the
feed wheel, gripper
plates and the cutter,
e.g. by means of
compressed air, at
regular intervals,
depending on use.