Packaging 

1.5

The sample order packaging contains the product and this manual. For large quantity orders, packaging may 
vary and TiMOTION reserves the right to change it.

 

 

Support 

1.6

If any technical support or information is needed for this product, please contact your TiMOTION sales 
engineer. You can also visit https://www.TiMOTION.com/en for the product or contact information. 

 

 

Disclaimer 

1.7

This user manual has been written based on our current technical knowledge. TiMOTION is constantly 
working on updating the product information. We reserve the right to carry out technical modifications. 

 

 

Notification and warnings 

1.8

 

1.8.1 Mounting/dismounting the actuator   

 

Please read through this user manual before working on the equipment that the actuator is or shall be a 
part of. 

 

Adhere to the information contained in this user manual and on the product label. Never exceed the 
performance limits stated herein. 

 

Be sure the actuator is not in operation. 

 

Ensure the actuator is free from loads that could be released during mounting or dismounting. 

 

Refrain from unplugging any cables or connectors during operation or with power on. 

 

Immediately stop using the actuator if it seems faulty or damaged. Notify your TiMOTION sales 
engineer so corrective actions can be taken. 

 

Never disassemble the actuator, as that will compromise the sealing and could impact the function of 
the actuator. Disassembly voids warranty. 

 

Grease may be present on the extension tube. Contact with the grease is non-hazardous. Please refrain 
from removing the film.   

 

1.8.2 Operation 

 

Be sure the actuator is correctly mounted as indicated in the user instructions. 

 

Be sure the equipment can be moved easily over the actuator’s whole working area. 

Содержание TA2P

Страница 1: ...User Manual TA2P Version C May 2020 1 of 21 A User Manual TA2P...

Страница 2: ...Cable 9 2 2 3 Inrush current 10 Wiring definitions 11 2 3 2 3 1 Limitations for limit switches output signals 11 2 3 2 Two limit switches to cut the current without signal output 12 2 3 3 Two limit sw...

Страница 3: ...stroke Low LS Lower limit switch is installed in fully retracted end of stroke Mid LS Middle limit switch is installed and the position is set by customer s request N C It is the pin of limit switch w...

Страница 4: ...get Personnel 1 2 Please allow qualified mechanical and electrical professionals perform all installation maintenance and replacement of the TiMOTION products Please keep the products away from people...

Страница 5: ...nt that the actuator is or shall be a part of Adhere to the information contained in this user manual and on the product label Never exceed the performance limits stated herein Be sure the actuator is...

Страница 6: ...here is no side load present on the actuator Only use the actuator within the specified working limits Refrain from having any contact with the actuator 1 8 3 Equipment power off Switch off the main s...

Страница 7: ...threaded at both ends of the attachments Do not mount the actuator with the pins in different rotated angles this could cause stress on the nut during operation The load should act along the stroke ax...

Страница 8: ...ease ensure it is able to withstand the peak of high voltage To reduce the chance of interference refrain from placing signal cables along power cables Use a two wire system to prevent ground loop Ple...

Страница 9: ...wer cable 20AWG 2 2 2 Cable The actuator is supplied with a power cable and or signal cable The standard cable for industrial applications has have flying leads in the end for the user s equipment con...

Страница 10: ...or starts to work there is an inrush current to the motor that will be less than 0 2 seconds up to four times the rated current Please select a power supply that is able to withstand the inrush curren...

Страница 11: ...function limitations for limit switches to output signals are shown in the table below Functions for limit switches Signal output Without POT Single Hall Double Hall 2 limit switches to cut the curre...

Страница 12: ...nt of the motor when the actuator moves to the end of each stroke and without any output signal Wire AWG Description Spec Yellow 20 Connect to Vm to extend the actuator Connect to Vm to retract the ac...

Страница 13: ...Input voltage 18 32 V DC 12V version Input voltage 9 16 V DC Green 20 Connect to Vm to extend the actuator Connect to Vm to retract the actuator White 26 Connect to common pin C The signal is potentia...

Страница 14: ...nput voltage 9 16 V DC Green 20 Connect to Vm to extend the actuator Connect to Vm to retract the actuator Red 26 Connect to common pin C The signal NOT potential free actively outputs voltage at the...

Страница 15: ...m to retract the actuator 24V version Input voltage 18 32 V DC 12V version Input voltage 9 16 V DC Green 20 Connect to Vm to extend the actuator Connect to Vm to retract the actuator Red 26 Connect to...

Страница 16: ...ct to Vm to retract the actuator 24V version Input voltage 18 32 V DC 12V version Input voltage 9 16 V DC Green 20 Connect to Vm to extend the actuator Connect to Vm to retract the actuator Red 26 5V...

Страница 17: ...ge 18 32 V DC 12V version Input voltage 9 16 V DC Green 20 Connect to Vm to extend the actuator Connect to Vm to retract the actuator Red 26 5V DC input signal power for Hall sensor board Hall sensor...

Страница 18: ...or 24V version Input voltage 18 32 V DC 12V version Input voltage 9 16 V DC Green 20 Connect to Vm to extend the actuator Connect to Vm to retract the actuator White 26 POT signal ground POT output si...

Страница 19: ...User Manual TA2P Version C May 2020 19 of 21 3 Product specifications 2D drawings 3 1 With POT or Reed Sensor Without sensor or with Hall sensors...

Страница 20: ...User Manual TA2P Version C May 2020 20 of 21 Ordering key 3 2 Please contact your TiMOTION sales engineer for the latest revision ordering key...

Страница 21: ...the external control unit Customer fuse burned Check the fuse Cable damaged Please contact your TiMOTION sales engineer Excessive power consumption Misalignment or overload in the application Align o...