User Manual-TA2P
Version C May 2020
15 of 21
15
2.3.5 Two limit switches send the signal output
The actuator is equipped with two limit switches. When the actuator moves to the end of each stroke, each
limit switch sends out the end of stroke voltage signal at the same time.
Wire
AWG
Description
Spec
Yellow
20
Connect to Vm+ to extend the actuator
Connect to Vm- to retract the actuator
24V version: Input voltage 18~32 V DC
12V version: Input voltage 9~16 V DC
Green
20
Connect to Vm- to extend the actuator
Connect to Vm+ to retract the actuator
Red
26
Connect to common pin (C.)
The signal is potential free and
independent from the motor power circuit.
The signal is short circuit when the
actuator moves to each end of stroke.
Connect the limit switches signal with
max 32V, <1A.
White
26
Connect to up limit switch normal closed
pin (N.C.)
Blue
26
Connect to low limit switch normal closed
pin (N.C.)
Yellow
Green
Red
White
Blue