background image

Page 5 

6: File download failed 
7: RF self-test failed 

 
 

Amber + 
Green 

LED’s On solid indicate unit is 
attempting to connect to the server. 

Amber + Green double flash 
to indicate a successful 
connection to the server. 

 
 

Amber + 
Green +  
Red 

All three LED’s on solid indicate the 
unit is powering up. If this does not 
clear, please contact support. 

Indicates a sensor is being 
activated (and matched if 
sensor matching is enabled). 

 

3 Installing the Broadband Modem 

Please unpack the broadband modem from the packaging and screw the 
antenna onto the unit, if it is not already pre-installed.  

 

The Ethernet port (right hand of the picture) must be connected to your internet 
high speed connection router. No additional bridges or routers are required. The 
modem should have “line of sight” to the tank sensor transmitter and should not 
exceed 250ft of distance.  

Please note that the distance will decrease with obstacles such as walls or glass 
between the modem and the transmitter. 

The Ethernet-cable delivered is approximately 1m/3ft long, but a longer cable of 
up to 100m/328ft can be used. 

The left plug in the picture above is for the power supply, which is also delivered 
in the packaging.  

Upon correct installation and activation the green LED light in the corner of the 
Ethernet plug will blink. If this light remains off, the connection to the Router is 
faulty. 

Содержание TEK-608A

Страница 1: ...Operating Instructions TEK 608A Broadband Modem with Ultrasonic Sensor V1 072017...

Страница 2: ...Interacting with the Modem via a Browser 8 9 Online Setup 12 10 Troubleshooting 12 1 No RF reading received for 6 hours 12 2 MAC Address IP link failed 12 3 No valid IP 12 4 Unable to connect to Serv...

Страница 3: ...ks can be read in a diagram showing the consumption over time as well as the current level and remaining days of supply The tanks can also be set up as tanks that are filling up i e Waste liquid tanks...

Страница 4: ...unction Amber Power LED On solid when Power is on Green RF Data LED Flashes when RF data packet is received During firmware download process it will flash rapidly Red Error LED Display Erro Flash Code...

Страница 5: ...The Ethernet port right hand of the picture must be connected to your internet high speed connection router No additional bridges or routers are required The modem should have line of sight to the ta...

Страница 6: ...synchronized Tanks with 1 and 1 NPT openings or European style double wall tanks require adapters see parts sold separately Do not use an extension pipe when mounting the adapter this can cause inaccu...

Страница 7: ...or 5 seconds and will no longer be flashing The unit will not immediately try to connect to the server and then revert to the listen mode Also consult the online video 6 Fitting the Sensor For tanks w...

Страница 8: ...e networks router the System Dashboard page can be viewed in a web browser In order to connect to the modem use the following URL HTTP TEK608 XXXX The XXXX must be replaced with the last 4 digits of t...

Страница 9: ...or that was matched in the previous process shows up named Sensor 1 to Sensor 4 automatically Setup Wizard On the Setup Wizard Page the name of the sensor transmitter can be renamed and a new more des...

Страница 10: ...selected and the Next button is clicked the Broadband modem is set to the Learn Mode and the screen below is shown A magnet needs to be held to the Transmitter Sensor at the black dot or the sensor i...

Страница 11: ...ial number will be pre filled The transmitter sensor is now matched with the Broadband modem The screen will not be showing that data is being received from the newly matched sensor Once the transmitt...

Страница 12: ...not receive any signal from the sensor transmitter This is usually when there is no direct line of sight an unusual obstacle or the sensor transmitter was not properly matched Please refer to the matc...

Страница 13: ...should not occur in normal operation There might be however a network issue preventing the remote servers reply to make it back to the Broadband modem Please contact customer service in this case 6 F...

Страница 14: ...hium cell up to 10 years Dimensions modem Indoor use only 120 x 25 x 72 mm 4 7 x 1 x 2 8 inch Max and min operating temp transmitter Operating temperature range 14 F to 140 F Operating humidity 0 100...

Страница 15: ...eries in a potentially explosive atmosphere Do not discard batteries in a pressurized container Warranty Registration Please register your product for warranty at https www tankmonitoring net warranty...

Отзывы: