3

3. Technical Specifications

•  230V AC 50 Hz
•  This PIR light controller is of class II construction and must not be earthed 
•  Motion Detection Range: 

 Up to 8 to 12 metres  
at a 2.5m mounting height

•  Detection Angle: 

180°

•  Maximum Switching Load: 

 1000W Halogen lighting, 
200W Fluorescent & LED lighting

•  Time ON Adjustment: 

3 seconds to 18 minutes.

•  Dusk Level Adjustment: 

 10 to 1000 Lux, Day and night  
or night time only operation

•  Pan/Tilt Adjustment: 

Pan left and right 45°, Tilt down 35°

•  Manual Override: 

6 hours max

•  Warm-up Time: 

60 seconds

•  Operating Temperature: 

-20°C to + 40°C

•  IP55 Rated suitable for restricted external applications
•  CE Compliant 
•  Dimensions: 

H=76mm, W=76mm, D=87mm

•  Multiple PIR light  

controller switching: 

 A maximum of 5 STLB/W1000 PIR light 
controllers can be wired in parallel,  
to enable any detector to turn ON  
all the lights connected.  
The total load must not exceed the lamp 
rating of a single STLB/W1000 unit.

Содержание SureTime STLB1000

Страница 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s 180 PIR Light Controller Model STLB1000 Black Model STLW1000 White...

Страница 2: ...d the circuit supply fuses are removed or the circuit breaker turned off It is recommended that a qualified electrician is consulted or used for the installation of this PIR light controller and insta...

Страница 3: ...t 10 to 1000 Lux Day and night or night time only operation Pan Tilt Adjustment Pan left and right 45 Tilt down 35 Manual Override 6 hours max Warm up Time 60 seconds Operating Temperature 20 C to 40...

Страница 4: ...TOWARDS See image B Therefore position the unit so that the sensor looks ACROSS the likely approach path Avoid positioning the sensor where there are any sources of heat in the detection area extracto...

Страница 5: ...tion 1 Mark the position of the mounting holes using the back plate as a template Drill out the mounting holes taking care to avoid any joists electrical cables or water gas pipes that may be hidden b...

Страница 6: ...rect polarity is observed and that all bare conductors are sleeved See section 6 Connection Diagram Line the PIR light controller up with the back plate apply pressure to both sides of the unit until...

Страница 7: ...V 50Hz mains supply and load cables into the terminal block as follows 230V 50Hz Mains Supply Live Supply Brown or Red to L Neutral Supply Blue or Black to N Load Light Source Switch Live Brown or Red...

Страница 8: ...ockwise Dusk Lux level setting fully clockwise Turn the power to the unit ON The lamp will immediately illuminate as the unit goes through its warm up period After approximately 1 minute the lamp will...

Страница 9: ...s reached where the lamp illuminates 3 Leave the control knob set at this point At this position the unit should become operative at approximately the same level of darkness each evening Observe the o...

Страница 10: ...witched ON at the power supply or isolation switch Turn OFF the power to the unit and check the wiring connections Check the lamp if it s changeable If the lamp has failed replace Ensure the lamp is s...

Страница 11: ...arantee In the unlikely event of this product becoming faulty due to defective material or manufacture within 2 years of the date of purchase please return it to your supplier in the first year with p...

Страница 12: ...l csc timeguard com For a product brochure please contact If you experience problems do not immediately return the unit to the store Telephone the Timeguard Customer Helpline Qualified Customer Suppor...

Отзывы: