Timeguard SureTime STLB1000 Скачать руководство пользователя страница 10

9

10. Troubleshooting

Problem

•   The lamp stays ON  

at night.

•   The PIR keeps 

activating for no 
reason at random.

•   The PIR will not 

operate at all.

Solution

Cover the PIR lens with a thick cloth. If the light  
turns OFF, check the detection area for heat or a 
reflective source. If the light stays ON, check the wiring 
(See section 6. Connection Diagram).

Turn OFF at the isolation switch. Turn back ON again 
after 30 seconds. Leave for approximately 15 minutes. 

If the light activates, check for false activation from 
heat, wind or a reflective source.

Check that the power is switched ON at the power 
supply or isolation switch. 

Turn OFF the power to the unit and check the wiring 
connections. Check the lamp (if it’s changeable). If the 

lamp has failed, replace. Ensure the lamp is seated 

correctly in the lamp-holder. Please note that the unit 

will not detect through glass (e.g. in a glazed porch).

9. Manual Override Mode 

The light can be switched ON for longer time periods by use of the Manual 
Override Mode. This can be activated at night by using the isolation switch. 
•  Switch the isolation switch once (OFF/ON) within 1.5 seconds.
•  The unit will now illuminate continuously for approximately 6 hours  

or until it is switched back into Auto Mode.

•  To return to Auto Mode switch the isolation switch OFF and then  

back ON again within 1.5 seconds.

Содержание SureTime STLB1000

Страница 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s 180 PIR Light Controller Model STLB1000 Black Model STLW1000 White...

Страница 2: ...d the circuit supply fuses are removed or the circuit breaker turned off It is recommended that a qualified electrician is consulted or used for the installation of this PIR light controller and insta...

Страница 3: ...t 10 to 1000 Lux Day and night or night time only operation Pan Tilt Adjustment Pan left and right 45 Tilt down 35 Manual Override 6 hours max Warm up Time 60 seconds Operating Temperature 20 C to 40...

Страница 4: ...TOWARDS See image B Therefore position the unit so that the sensor looks ACROSS the likely approach path Avoid positioning the sensor where there are any sources of heat in the detection area extracto...

Страница 5: ...tion 1 Mark the position of the mounting holes using the back plate as a template Drill out the mounting holes taking care to avoid any joists electrical cables or water gas pipes that may be hidden b...

Страница 6: ...rect polarity is observed and that all bare conductors are sleeved See section 6 Connection Diagram Line the PIR light controller up with the back plate apply pressure to both sides of the unit until...

Страница 7: ...V 50Hz mains supply and load cables into the terminal block as follows 230V 50Hz Mains Supply Live Supply Brown or Red to L Neutral Supply Blue or Black to N Load Light Source Switch Live Brown or Red...

Страница 8: ...ockwise Dusk Lux level setting fully clockwise Turn the power to the unit ON The lamp will immediately illuminate as the unit goes through its warm up period After approximately 1 minute the lamp will...

Страница 9: ...s reached where the lamp illuminates 3 Leave the control knob set at this point At this position the unit should become operative at approximately the same level of darkness each evening Observe the o...

Страница 10: ...witched ON at the power supply or isolation switch Turn OFF the power to the unit and check the wiring connections Check the lamp if it s changeable If the lamp has failed replace Ensure the lamp is s...

Страница 11: ...arantee In the unlikely event of this product becoming faulty due to defective material or manufacture within 2 years of the date of purchase please return it to your supplier in the first year with p...

Страница 12: ...l csc timeguard com For a product brochure please contact If you experience problems do not immediately return the unit to the store Telephone the Timeguard Customer Helpline Qualified Customer Suppor...

Отзывы: