Parallel Switching
• A maximum of 4x LED100PIR single floodlights can be wired in parallel
to enable any detector to turn ON all the lights connected.
• Please refer to the following diagram which shows and example
of 2x LED100PIR single floodlights connected in parallel,
with 2 slave floodlights at the same time:
7. Setting Up
Walk Test Procedure (Test Mode)
• Make sure the PIR sensor is set to Test Mode i.e. the TIME ON Adjustment
to the minimum (fully anti-clockwise), and the Lux Level set the Sun symbol
(fully clockwise). We recommend using the knob adjuster included in the
accessory pack to adjust the Time and Lux settings, however a thin flat head
screwdriver or a 2.5mm Allen key could also be used.
• Turn the power to the unit ON.
See image 8. The lamp will immediately
illuminate as the unit goes through
its “warm-up” period. After approximately
30 seconds the lamp will extinguish.
This indicates the unit is wired correctly
and the unit is in Test Mode.
• Try to remain outside the detection
area during the warm-up period.
8