8

•  The unit will now operate during daytime as well as at night, illuminating the 

lamp for approx. 2 seconds each time. This allows testing to be carried out to 
establish whether the sensor is covering the required area.

•  Walk across the location the sensor is fitted, to establish the detection zone.
•  The sensor will detect you approximately up to 10 meters forward at mounting 

height of 2.5m.

•  As you cross the detection “zone” the lamp will illuminate. Now stand still  

until the lamp extinguishes (this should take approx. 2 seconds).

•  Start moving again after 5 seconds. Each time you cross the detection “zone” 

the lamp will illuminate.

•  Repeat the above, walking at various distances and angles to the unit.  

This will help you to confirm the detection pattern.

Setting Up for Automatic Operation (Auto Mode)

•  When walk tests are complete, the unit can be adjusted for automatic operation.
•  The TIME ON adjustment controls how long the unit remains illuminated 

following activation and after all motion ceases. 

•  Use a thin flat blade screwdriver to make adjustments. We recommend using 

the knob adjuster included in the accessory pack to adjust the Time and Lux 
settings, however a thin flat head screwdriver or a 2.5mm Allen key  
could also be used.

•  This can be set between 2 seconds to a maximum of 30 minutes.
•  Set the control to the desired setting between these limits.
•  The LUX Level adjustment determines the level of darkness required for the unit 

to start operating. The setting is best achieved by the procedure below;

  1.  Set the LUX Level adjustment knob fully clockwise (Sun symbol). 
  2.  When the ambient light level reaches the level of darkness at which you  

  wish the lamp to become operative (i.e. at dusk) SLOWLY rotate the  
  control in an anti-clockwise direction until a point is reached where  
  the lamp illuminates. 

  3.  Leave the control set at this point.
•  At this position the unit should become operative at approximately  

the same level of darkness each evening.

•  Observe the operation of the unit. If the unit is starting to operate  

too early (i.e. when it is quite light) adjust the control slightly anti-clockwise.  

Содержание LED100PIRBE

Страница 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s 10W LED Slimline PIR Floodlight Single Flood Model LED100PIRBE Black Model LED100PIRWHE White...

Страница 2: ...g when this luminaire is fitted does not exceed the rating of the circuit cable fuse or circuit breaker 3 Technical Specifications 230V AC 50Hz This luminaire is of class I construction and must be ea...

Страница 3: ...time Back Box Mounting Centres 60mm IP55 Rated suitable for restricted external applications CE Compliant Dimensions H 160mm W 80mm D 50mm Other Loads External Slave LED Lamp Max 100W Halogen Lamp Max...

Страница 4: ...movement directly TOWARDS See image C Therefore position the floodlight so that its PIR sensor looks ACROSS the likely approach path Avoid positioning the floodlight where there are any sources of he...

Страница 5: ...n the wall using the back box as a template See image 4 Drill the holes ensuring not to infringe with any gas water pipes or electrical cables that may be hidden below the surface Insert the rawl plug...

Страница 6: ...image 6 ensuring correct polarity is observed and that all bare conductors are sleeved See section 6 Connection Diagram for wiring details 5 8 Re connect the luminaire to the back box ensuring the 2 l...

Страница 7: ...erminal block on the back box as follows Live Supply Brown or Red to L Neutral Supply Blue or Black to N Earth Green Yellow to For additional external slave lighting connect the external load to the t...

Страница 8: ...e PIR sensor is set to Test Mode i e the TIME ON Adjustment to the minimum fully anti clockwise and the Lux Level set the Sun symbol fully clockwise We recommend using the knob adjuster included in th...

Страница 9: ...owing activation and after all motion ceases Use a thin flat blade screwdriver to make adjustments We recommend using the knob adjuster included in the accessory pack to adjust the Time and Lux settin...

Страница 10: ...time only by using the internal wall switch or circuit breaker Switch the internal wall switch twice OFF ON OFF ON within 2 seconds The floodlight will now illuminate continuously for 6 hours or until...

Страница 11: ...responsible for all shipping postage charges outside of the UK All shipping costs are to be paid in advance before a replacement is sent You are able to add an additional 6 hours ON time by switching...

Страница 12: ...csc timeguard com For a product brochure please contact If you experience problems do not immediately return the unit to the store Telephone the Timeguard Customer Helpline Qualified Customer Support...

Отзывы: