background image

3

5. Installation

5.1  Ensure the mains supply is switched off and the 

circuit supply fuses are removed or the circuit 
breaker turned OFF (See image 1).

•  A moving human body needs to cross/enter 

one of these zones to activate the PIR sensor. 
The best all-round coverage is achieved with 
the floodlight mounted at the optimum height 
of 2.5 metres. See image B.

•  Careful positioning of the PIR sensor will be required  

to ensure optimum performance.

•  The PIR sensor is more sensitive to movement ACROSS  

its field of vision than to movement directly TOWARDS  
(See image C). Therefore position the floodlight so that  
its PIR sensor looks ACROSS the likely approach path.

•  Avoid positioning the floodlight where there are any 

sources of heat in the detection area of its PIR sensor 
(extractor fans, tumble dryer exhausts etc.) including 
opposite any other light sources such as other  
security floodlights.

•  Reflective surfaces (i.e. pools of water or white painted walls) and overhanging 

branches may cause false activation under extreme conditions.

•  During extreme weather conditions the PIR sensor may exhibit unusual 

behaviour. This does not indicate a fault with the product. Once normal  
weather conditions return, the PIR sensor will resume normal operation.

B

1

C

Содержание LED100PIRBE

Страница 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s 10W LED Slimline PIR Floodlight Single Flood Model LED100PIRBE Black Model LED100PIRWHE White...

Страница 2: ...g when this luminaire is fitted does not exceed the rating of the circuit cable fuse or circuit breaker 3 Technical Specifications 230V AC 50Hz This luminaire is of class I construction and must be ea...

Страница 3: ...time Back Box Mounting Centres 60mm IP55 Rated suitable for restricted external applications CE Compliant Dimensions H 160mm W 80mm D 50mm Other Loads External Slave LED Lamp Max 100W Halogen Lamp Max...

Страница 4: ...movement directly TOWARDS See image C Therefore position the floodlight so that its PIR sensor looks ACROSS the likely approach path Avoid positioning the floodlight where there are any sources of he...

Страница 5: ...n the wall using the back box as a template See image 4 Drill the holes ensuring not to infringe with any gas water pipes or electrical cables that may be hidden below the surface Insert the rawl plug...

Страница 6: ...image 6 ensuring correct polarity is observed and that all bare conductors are sleeved See section 6 Connection Diagram for wiring details 5 8 Re connect the luminaire to the back box ensuring the 2 l...

Страница 7: ...erminal block on the back box as follows Live Supply Brown or Red to L Neutral Supply Blue or Black to N Earth Green Yellow to For additional external slave lighting connect the external load to the t...

Страница 8: ...e PIR sensor is set to Test Mode i e the TIME ON Adjustment to the minimum fully anti clockwise and the Lux Level set the Sun symbol fully clockwise We recommend using the knob adjuster included in th...

Страница 9: ...owing activation and after all motion ceases Use a thin flat blade screwdriver to make adjustments We recommend using the knob adjuster included in the accessory pack to adjust the Time and Lux settin...

Страница 10: ...time only by using the internal wall switch or circuit breaker Switch the internal wall switch twice OFF ON OFF ON within 2 seconds The floodlight will now illuminate continuously for 6 hours or until...

Страница 11: ...responsible for all shipping postage charges outside of the UK All shipping costs are to be paid in advance before a replacement is sent You are able to add an additional 6 hours ON time by switching...

Страница 12: ...csc timeguard com For a product brochure please contact If you experience problems do not immediately return the unit to the store Telephone the Timeguard Customer Helpline Qualified Customer Support...

Отзывы: