W415-1473 / 04.22.15
EN
9
3.4 OUTSIDE
AIR
If possible connect the air intake at the pedestal’s back or bottom to the outside with a 4 inch diameter fresh air
kit available at your authorized dealer / distributor.
The following are signs that a fresh air kit may be required:
13 3/8"
340mm
11 11/16"
297mm
•
When there is combustion present: Wood burns poorly, smoke spills, back-draft takes place and your
chimney does not draw steadily.
•
In the winter there is too much condensation on the windows.
•
Opening a window seems to alleviate the above symptoms.
•
A ventilation system is installed in the house.
•
Other devices are present that exhaust house air.
•
The house has tight fi tting windows and/or is equipped with a well-sealed vapour barrier.
!
WARNING
IF ROOM AIR STARVATION OCCURS BECAUSE THE FRESH AIR INTAKE IS BLOCKED WITH ICE,
LEAVES, ETC., OR BECAUSE THE APPLIANCE DOOR WAS LEFT OPEN, OR DUE TO A STRONG
EXHAUST FAN OPERATING ETC., DANGEROUS FUMES AND SMOKE FROM THE OPERATING APPLI-
ANCE COULD BE DRAWN INTO THE ROOM.