WARNING
6.0 OPTIONAL KIT INSTALLATIONS
Drywall dust will penetrate into the blower
bearings, causing irreparable damage.
Care must be taken to prevent drywall
dust from coming into contact with the
blower or its compartment. Any damage
resulting from this condition is not
covered by the warranty policy. Use of the
blower increases the output of heat.
Provisions have been made on this
appliance to install an optional blower
kit (EP65) that comes complete with a
variable speed switch to turn the blower
ON/OFF, as well as adjusting the blower
speed.
A.
Ensure the thermal disc bracket is in the correct position.
B.
Remove the knock-out from the back of the appliance.
C.
Install the blower and housing as shown using
the 4 screws supplied.
D.
Loosen the thermal disc bracket (2 screws)
and slide the bracket until the thermal disc is
touching the rear of the fi rebox and secure.
Check that the thermal
switch bracket is
positioned as illustrated.
THERMAL SWITCH BRACKET
THERMAL DISC
BRACKET
SCREWS
KNOCKOUT
BLOWER
RISK OF FIRE AND ELECTRICAL SHOCK.
TURN OFF THE ELECTRICAL POWER BEFORE SERVICING THIS APPLIANCE.
USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH
THIS APPLIANCE. USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, ETC.)
COULD RESULT IN A SAFETY HAZARD AND WILL VOID THE WARRANTY AND CERTIFICATION.
USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH
THIS APPLIANCE. USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, ETC.)
COULD RESULT IN A SAFETY HAZARD AND WILL VOID THE WARRANTY AND CERTIFICATION.
6.1 OPTIONAL BLOWER INSTALLATION
Содержание Economizer EPA 2300
Страница 33: ...W415 1473 04 22 15 EN 33 43 1 12 0 SERVICE HISTORY...
Страница 34: ...W415 1473 04 22 15 EN 34 44 1 13 0 NOTES...
Страница 35: ...W415 1473 04 22 15 EN 35 44 1...
Страница 70: ...70 W415 1473 04 23 15 FR 44 1 13 0 NOTES...
Страница 71: ...71 W415 1473 04 23 15 FR 44 1...