IM2020
27
unplug the curtain, find out and eliminate what caused the emergency shutdown device to
trigger.
5. Turning off
To turn off the air curtain, turn temperature control knob clockwise to the end and let the device
run in ventilation mode for 3 minutes to cool the heating elements, then set the fan switch to the
“OFF” position and disconnect the device from the power supply.
ATTENTION!
In order to increase the life time of the air curtain, it is recommended to follow the above
mentioned instructions for turning off the device. Turning off the curtain without cooling the
heating elements first can cause overheating and premature failure of the heating elements.
9. MAINTANANCE
Subject to safety requirements and operating rules, the curtain does not require special
maintenance.
It is necessary to periodically (at least once a month) clean dust and dirt from the perforated air
intake grille and, if necessary, other external surfaces of the curtain.
10. TROUBLESHOOTING
If it is impossible to fix these malfunctions with these methods, contact the authorized service
center.
Malfunction
Possible cause
Solution
The device is connected
to the network but doesn’t
work.
No power
Check whether the power
supply is disconnected from
the device and, if necessary,
connect device to power
supply
Defective operation mode
switch
Contact an authorized service
center
Control cable of remote
controller is broken
Check the control cable,
replace broken control cable
or contact an authorized
service center
Remote controller is
connected incorrectly
Check the connection of the
remote controller, if necessary
change the connection
scheme or contact an
authorized service center
Operation mode switch is in
“Off” position
Set the switch to “On” position
Faulty contact connection in
wiring scheme of electrical
circuit
Contact an authorized service
center or restore reliable
contact connection
Malfunction in circuit breaker
Change the circuit breaker
Defective heating element
Contact an authorized service
center
Power cord is broken
Contact an
authorized service center to
fix it
Airflow does not heat up
Low voltage in power network
Check the voltage in power
network
The temperature limiter is off
Wait a few minutes so heating
elements can cool down.
Temperature limiter will turn
on eventually
Temperature limiter parted
Ensure that the air inlet or
Содержание Power Door Series
Страница 2: ...IM2020 2 1 2 1 2 3 4 5 6...
Страница 3: ...IM2020 3 7 8 9 10 11 12 13 0 C 2 14 15 16 17 18 19 20 21 22 23 24 25 26 3 27 28 29 30 31 32 93...
Страница 9: ...IM2020 9 8 THC W 1 3M THC WT1 5M 3 1 2 THC WT1 3M THC WT1 5M 1 1 1 0 1 2 1 3 2 2 2 2 1...
Страница 10: ...IM2020 10 2 2 10 20 3 4 3...
Страница 12: ...IM2020 12 2 2 1 I 2 2 II 10 20 3 3 1 5 30 3 2 3 3 4 5 3 OFF 9...
Страница 13: ...IM2020 13 10 3 3...
Страница 14: ...IM2020 14...
Страница 15: ...IM2020 15 11 THC W 1 3M 5 1 EK2 1 M2 SA1 SA2 SK1 SK2 1 XT1 THC W 1 5M 6...
Страница 16: ...IM2020 16 1 2 1 1 SA1 SA2 SK1 SK2 THC W 1 6M THC W 1 9 7 A1 C1 EK1 EK6 KM1 KM2 1 SK1 SK2 SK3 XT1 XT2...
Страница 17: ...IM2020 17 THC WT1 12M THC WT1 18M THC WT1 24M 8 A1 C1 EK1 EK6 KM1 KM2 1 SK1 SK2 SK3 XT1 XT2 12...
Страница 32: ...www timberk ru...