30. It is forbidden to use the curtain with the removed covers.
31. It is forbidden to use software devices and timers that automatically turn on the curtain.
32. It is forbidden to operate the curtain in rooms with a relative humidity of more than 93%,
with a biologically active environment, with a dusty environment, with an explosive
atmosphere and with a chemically active environment that destroys metals and
insulation.
33. The device is not intended for use by persons (including children) with reduced
physical, sensory or mental abilities or in the absence of their life experience or
knowledge, unless they are supervised or instructed on the use of the device by the
person responsible for their safety.
34. Explanation of warning signs:
Caution! Hot surface
Attention! Do not cover
3. APPOINTMENT OF THE DEVICE
The electric air curtain is designed to protect the premises from the penetration of cold outside
air, to reduce heat loss inside the room, to maintain a comfortable temperature in installation
zone of the curtain. Also, with the heating elements turned off, it can be used in summer to
protect the air-conditioned room from penetrating warm outside air, dust, smoke, insects, etc.
The curtain is designed for operation in closed rooms with an air temperature from -
10°C to +
40°C, with a relative humidity of not more than 93%, in conditions that exclude water drops,
splashes and precipitation (climatic execution
УХЛ 3.1 in accordance with ГОСТ 15150).
4. SPECIFICATIONS
Technical parameters
Technical parameters are indicated in table 1
Table 1
Parameter
Unit
THC
WT1
3M
THC
WT1
5M
THC
WT1
6M
THC
WT1
9M
THC
WT1
12M
THC
WT1
18M
THC
WT1
24M
Power
supply
V/Hz
220~
/50
220~
/50
380~
/50
380~
/50
380~
/50
380~
/50
380~
/50
Rated
current
А
13.7
20.5
9.1
13.7
18.5
27.5
36.4
Rated power
consumption
W
3000
4500
6000
9000
12000
18000
24000
Power
modes
W
0/1500/
3000
0/2250/
4500
0/3000/
6000
0/4500/
9000
0/6000/
12000
0/9000/
18000
0/12000
/24000
Rated fan
output
m
3
/h
600
1000
1500
1900
3200
3200
3200
Average
outlet air
velocity
m/sec
7.5
7.6
8
8
8
8
8
Outlet air
temperature
increase
at maximum
heating
0
С
17
14
14
15
12
18
24
Содержание Power Door Series
Страница 2: ...IM2020 2 1 2 1 2 3 4 5 6...
Страница 3: ...IM2020 3 7 8 9 10 11 12 13 0 C 2 14 15 16 17 18 19 20 21 22 23 24 25 26 3 27 28 29 30 31 32 93...
Страница 9: ...IM2020 9 8 THC W 1 3M THC WT1 5M 3 1 2 THC WT1 3M THC WT1 5M 1 1 1 0 1 2 1 3 2 2 2 2 1...
Страница 10: ...IM2020 10 2 2 10 20 3 4 3...
Страница 12: ...IM2020 12 2 2 1 I 2 2 II 10 20 3 3 1 5 30 3 2 3 3 4 5 3 OFF 9...
Страница 13: ...IM2020 13 10 3 3...
Страница 14: ...IM2020 14...
Страница 15: ...IM2020 15 11 THC W 1 3M 5 1 EK2 1 M2 SA1 SA2 SK1 SK2 1 XT1 THC W 1 5M 6...
Страница 16: ...IM2020 16 1 2 1 1 SA1 SA2 SK1 SK2 THC W 1 6M THC W 1 9 7 A1 C1 EK1 EK6 KM1 KM2 1 SK1 SK2 SK3 XT1 XT2...
Страница 17: ...IM2020 17 THC WT1 12M THC WT1 18M THC WT1 24M 8 A1 C1 EK1 EK6 KM1 KM2 1 SK1 SK2 SK3 XT1 XT2 12...
Страница 32: ...www timberk ru...