background image

 

 

CAROBNA HYDRO                                                  

 

                                                     

6

20

 

 

INSTALING THE STOVE 

 
 

Stove  must  not  be  set  up near  the wooden  parts,  refrigeration  devices,  plastic  furniture  and  other 

flammable  materials  because  during  operation  (during  fuel  combustion)  it  achieves  high  operating 
temperature that is distributed on the outside of the furnace. Minimum distance between the stove and the 
surrounding elements is 50 cm, and the from flammable materials 80 cm. 
 

If  the  ground  on  which  you  set  the  stove  is made of  easily  flammable material  (wood, warm  floor, 

laminate ...) you need to set under the stove a protection sheet metal - lateral width of 10 cm and 50 cm in 
the front. 
 

Because  of  its  weight,  the  stove  must  be  installed  on  the  appropriate  base.  If  it  does  not  satisfied 

necessary standard, you must take appropriate measures to make it possible (e.g., weight distribution). 
Connect the stove to a chimney and flue pipes through the connector on top of the furnace, so as to ensure 
adequate  tightness  and  flow  of  smoke  from  the  stove  to  the  chimney.  Flue  pipe  must  not  be  drawn  too 
deeply  into  the  chimney  that  would  reduce  the  cross  sectional  area  and  thus  undermined  draft  in  the 
chimney. Do not use reducers which reduce the cross section of pipe smoke. 
 

The stove requires insertion of fresh air in the room where it is installed, with surface openings for 

insertion of fresh air should not be less than 0.4 dm ². The unit for fresh air set outside the common room for 
ventilation, which must be insured by door and grids. 
 

Fans that work in the same room where the stove is installed may make interference with stove. Also, 

all devices or ventilation that creates negative pressure in the room where the stove is installed, must be set 
in the way that does not make decompression that prevents normal operation of the furnace. 
Before installing the stove, check the chimney drafts because it is a key factor in the proper functioning of the 
stove.  Draft  depends  on  the  proper  operation  of  the  chimney  and  meteorological  conditions.  One  of  the 
easiest ways to check the draft in the chimney is with a candle flame, as shown in Figure 3 . Put a candle near 
the chimney connection drain. If the flame bends towards drain, the draft is satisfying (Figure 3b). If the flame 
doesn’t bend or bends a little, that indicates poor draft(Figure 3a). 
 

If there is poor draft in the chimney (Figure 3a), check the chimney operation. The chimney should be 

located  inside  the  building,  and  if  it’s  located  on  the  external  walls  of  the  building,    it’s  recommended 
insulation chimney. 
 
 

 

 
                                Fig. 3a.                                                                                        Fig. 3b. 
 
 

Содержание CAROBNA HYDRO

Страница 1: ...CAROBNA HYDRO Owners s manual INSTALATION ADJUSTMENT AND OPERATING INSTRUCTION EN 13240 ...

Страница 2: ... Keep it handy and refer to it as needed You will find in it information that will be useful now and in the years to come Make sure that when installing the stove all security standards have been respected and that all water pipes connections between tubes and pipes and walls are connected properly Failure to comply with these standards and carelessness during installation can result in damage to ...

Страница 3: ...econdary air 10 INSTALATION OF STOVE IN SYSTEM FOR CENTRAL HEATING 10 Instalation on closed central heating system 11 InatLtion on the open central system 12 CLEANING AND MEINTENANCE 13 MALFUNCTION RECOMMENDATION FOR ITS SLIMINATION 14 GENERAL RECOMENDATION 14 ADVICES FOR ENVIROMENT PROTECTION 15 Packaging 15 Product 15 DECLERATION OF GUARANTEE Error Bookmark not defined ...

Страница 4: ...ndling it Do not allow children to handle and play near the stove Only spare parts recommended and allowed by the manufacturer should be installed on the stove You must not make any changes on the stove With first firing there might show a mild smoke especially from the plate s surface It is a common appearance that occurs due to combustion deposits on the plate s surface corrosion protection pain...

Страница 5: ...e is made of steel fig 1 pos 1 Firebox doors fig 1 pos 6 are made of steel with fireproof glass Connection for smoke drains being put on the plate and connected with screws fig 1 pos 2 and are made of cast iron All the materials that CAROBNA HYDRO stove is made can be recycled Sealing elements are made of materials that NOT contain asbestos The grid in the combustion chamber fig 1 pos 8 is made of...

Страница 6: ...ired draft Pa 12 15 Hydro stove with back boiler are intended for heating residential space An integral part of the installation is a temperature safety relief valve for thermal discharge that serves as thermo safety of possible overheating It is recommended Caleffi 544 shown in Figure 2 Fig 2 Function Drain valve for thermal protection limits the water temperature They are intended for cooling of...

Страница 7: ...s which reduce the cross section of pipe smoke The stove requires insertion of fresh air in the room where it is installed with surface openings for insertion of fresh air should not be less than 0 4 dm The unit for fresh air set outside the common room for ventilation which must be insured by door and grids Fans that work in the same room where the stove is installed may make interference with st...

Страница 8: ...2 Too large slope 3 Abrupt alteration of the direction of smoke channel 4 Stove or other device connected to the same smoke channel 5 Bulges in the smoke channel 6 Cranks 7 Foreign body or deposited smut 8 Too deep installed pipe 9 Ventilator or other device which createssub pressure in the room 10 Leaky or open aperture for cleaning ...

Страница 9: ...g primary air regulator and secondary air over the leverage above the firebox door Fig 1 pos 3 you get desired combustion Stove contains auxiliary tools in order to facilitate its maintenance Recommended fuels are briquettes and wood You must not use gasoline and similar fuels because by using liquid fuels you create conditions for damaging the stove and to provoke an explosion Attention Do not us...

Страница 10: ...c smell of burning If there comes to the fire do the following Immediately call the fire squad muffle oxygen supply to the chimney and turn off the stove Do not insert anything into the chimney and make sure that the fire does not spread to the wooden construction or other combustible materials in its nearby DO NOT pour water into the stove or chimney A fire in the chimney can be extinct only with...

Страница 11: ...f the safety valve should be carried out in the sewer Union coupling for easy assembly and disassembly in case of repairs On the return line is necessary to put Filling and emptying installations Union coupling for easy assembly and disassembly in case of repairs At the beginning of its operation it is necessary that The stove should be connected to the chimney Installation must be filled with wat...

Страница 12: ... installation of a four way mixing valve at certain place Figure 7a and 8a or a tubing pipe contact thermostat Figure 7b and 8b set to 55 C Their installation is required for the prevention of condensation on the walls of the boiler in the furnace condensation boiler adversely affect the service life of the boiler and on the performance of the product by creating a resin on the walls of the boiler...

Страница 13: ...boiler valve and on starting guide of the system boiler valve pump and valve are to be installed Directly below opened expansion vessel short connection should be installed between safety distribution guide and safety retracting guide which provides freezing of water during winter in the expansion vessel On safety distribution and safety retracted guide there may not be any armature Expansion vess...

Страница 14: ...inted surfaces must not be cleaned with abrasive products Cleaning inter surfaces when cleaning use protective gloves Clean the bottom of the fire chamber from accumulated ash and pick up small unburned pieces of the grid clean the ashtray and ash accumulated in the interior of the fireplace Cleaning glass surfaces glass on the firebox may get dirty during the operation For cleaning use a mild det...

Страница 15: ...apply advices how to provide secondary air Not enough heat in radiators Air in installation Power of radiators exceeded power of boiler Improper using Vent the radiators from the heating system turn off some of heating body Read carefully the instructions for using and maintenance GENERAL RECOMENDATION If you have full field all the recommendations for installation operation and control of cleanin...

Страница 16: ... as a potential source of danger Take care of safe removing and disposing of wooden boards because they are connected with nails Product The device is made of materials that can be recycled When disposing the waste act in accordance with environmental laws in effect Use only the recommended fuel It is forbidden burning an inorganic and organic materials plastics plywood textile oiled wood etc beca...

Страница 17: ...CAROBNA HYDRO 16 20 WOOD BURNING STOVE CAROBNA HYDRO ...

Страница 18: ... Inner stove Corpus 5 Boiler assembly 6 Deflector 7 The carrier grid 8 Wire for spreading 9 Bottom stove 10 Grid 11 Ashtray 12 Wrench 13 Bracket cup assembly 14 Door handle 15 Washer door handles 16 Primary regulator 17 Glass doors 18 Door 19 Pin 20 Decorative panel 21 Front furnace 22 Secondary air regulator 23 Screw nut ...

Страница 19: ...CAROBNA HYDRO 18 20 STOVE DIMENSION ...

Страница 20: ...19 TIM SISTEM d o o ul Prva industrijska 9 22330 Nova Pazova Serbia Tel fax 381 22 328 076 e mail office timsistem rs www timsistem rs ...

Отзывы: