CAROBNA HYDRO
10
/
20
I - regulation of secondary air
Set the secondary air in the closed position during firing and kept in this position until the establishment of
the working regime of burning after insertion of larger pieces of wood. After this time set the controller in
position open and hold it in this position all the time stove functioning. The secondary air is used to clean the
glass (air wash) on the firebox door and for better combustion.
Power regulation is the furnace is obtained by adjusting the regulator of the primary and secondary air
open closed
INSTALATION OF STOVE IN SYSTEM FOR CENTRAL HEATING
- For water inlet and outlet within the system of floor (central) heating are provided with adapters on boiler
1".
- Stove may be mounted on closed or open system of central heating.
For pressure pipe set user must have:
- Temperature and pressure gauge to indicate the pressure in the water system and the water temperature
at the boiler outlet.
- Safety valve (which opens at a water pressure of 2.5 bar) to put on the discharge pipe immediately behind
the boiler. The output of the safety valve should be carried out in the sewer.
- Union coupling , for easy assembly and disassembly in case of repairs.
On the return line is necessary to put:
- Filling and emptying installations
- Union coupling, for easy assembly and disassembly in case of repairs.
At the beginning of its operation it is necessary that:
- The stove should be connected to the chimney
- Installation must be filled with water (at a pressure of 1-1.5 bar), and the whole system vented.
- It is necessary that all the valves between the stove and installation are open
Note: Installation of heating and commissioning of the entire system should be entrusted to professional
person who guarantees the correct operation of the entire heating system. In case of bad design of the
system and possible failure in execution of works by that person, complete material solely the responsibility
of the person to whom it is entrusted installation of heating systems, not the manufacturer, of the boiler.
Important!
Installing the stove should be performed expertly face at a reasonable project. The design allows you to
connect the stove to an indoor or outdoor heating system. All connections must be well sealed and fastened.
Prior to commissioning, a complete installation shall be tested with water at a pressure of 3 bar.