TILLOTSON TPP-4500G-A Скачать руководство пользователя страница 9

 

 

 

Make sure the power switch is in its “OFF” position and disconnect the spark 
plug wire before making any adjustment, changing accessories, or storing the 
generator.  Such  preventative  safety  measures  reduce  the  risk  of  starting  the 
generator accidentally. 
 
Store  idle  generators  out  of  reach  of  children  and  other  untrained  persons. 
Generators are dangerous in the hands of untrained users. 
 
Maintain generators with care. Do not use a damaged generator. Tag damaged 
generators “Do not use” until repaired. 
 
Check  for  misalignment  or  binding  of  moving  parts,  broken  parts,  and  any 
other  condition  that  may  affect  the  generator’s  operation.  If  damaged,  have 
the  generator  serviced  before  using.  Many  accidents  are  caused  by  poorly 
maintained generators. 
 
Use  only  accessories  that  are  recommended  by  the  manufacturer  for  your 
model.  Accessories  that  may  be  suitable  for  one  generator  may  become 
hazardous when used on another generator. 

 

 

Servicing

 

 

 

Maintain  labels  and  nameplates  on  the  generator  and  engine.  These  carry 
important  information.  If  unreadable  or  missing,  contact  the  service  number 
on  the  front  page  of  this  manual  or  Tillotson  Power  Products  LLC 
immediately for a replacement. 
 
Generator  service  must  be  performed  only  by  qualified  repair  personnel. 
Service or maintenance performed by unqualified personnel could result in a 
risk of injury. 
 
When servicing a generator, use only identical replacement parts. Follow all 
appropriate instructions in this manual. Use of unauthorized parts or failure to 
follow maintenance instructions may create a risk of electric shock or injury. 

 

 

Heart Pacemakers

 

 

WARNING!  PEOPLE  WITH  PACEMAKERS  SHOULD  CONSULT 
THEIR 

PHYSICIAN(S) 

BEFORE 

USING 

THIS 

PRODUCT. 

ELECTROMAGNETIC  FIELDS  IN  CLOSE  PROXIMITY  TO  A 
HEART  PACEMAKER  COULD  CAUSE  INTERFERENCE  TO  OR 
FAILURE OF THE PACEMAKER. 

 

 

Installation 

 

Содержание TPP-4500G-A

Страница 1: ...ow all safety rules and instructions in this manual before attempting to operate this machine Failure to comply with these instructions may result in personal injury Diagrams within this manual may no...

Страница 2: ...HE GENERATOR 18 STOPPING THE GENERATOR 19 OPERATION INSTRUCTIONS 20 MAINTENANCE 22 STORAGE 25 INSTALLATION 26 TROUBLESHOOTING 27 WIRING DIAGRAM 29 MODEL SPECIFICATIONS 29 The engine exhaust from this...

Страница 3: ...s injury Read them carefully Please read the manual and pay attention to these sections Save These Important Safety Instructions Read and understand all of these safety instructions Be sure to retain...

Страница 4: ...HEN USING AIR TOOLS BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THE RISK OF PERSONAL INJURY Specific Warnings Carbon Monoxide When this tool is running ensure that the area is well ve...

Страница 5: ...MMABE MATERIALS NEAR THE GENERATOR Do not smoke or allow sparks flames or other sources of ignition around the engine and fuel tank Fuel vapors are explosive Keep grounded conductive objects such as t...

Страница 6: ...void body contact with grounded surfaces such as pipes radiators ranges and refrigerators There is an increased risk of electric shock if your body is grounded Do not abuse the power cord for your too...

Страница 7: ...ERATE THE GENERATOR WITH WET HANDS Do not attempt to connect or disconnect load connections while standing in water or on wet or soggy ground Do not touch electrically energized parts of the generator...

Страница 8: ...s Loose clothes jewelry or long hair can be caught in moving parts Avoid accidental starting Make sure the power switch is in its OFF position and disconnect the spark plug wire when not in use Remove...

Страница 9: ...your model Accessories that may be suitable for one generator may become hazardous when used on another generator Servicing Maintain labels and nameplates on the generator and engine These carry impor...

Страница 10: ...exhaust fumes must be within legal limits and installation must always meet local building codes If the generator is installed outdoors it must be weatherproofed and should be soundproofed It should n...

Страница 11: ...loose clothing and jewelry away from moving parts Be aware that when engine parts are moving fast they cannot be seen clearly Keep access doors on enclosures closed and locked when access is not requ...

Страница 12: ...ich could result in electrocution Do not connect to a building electrical system unless a qualified electrician has installed an isolation switch Fire and Burn Hazards The exhaust system gets hot enou...

Страница 13: ...13 GENERATOR COMPONENTS See next page for further explanations...

Страница 14: ...engine Return it gently to prevent damage to the starter When starting the engine by recoil starter set the key switch to the ON position and pull the recoil starter handle Fuel Valve The fuel valve...

Страница 15: ...ne damage caused by an insufficient amount of oil in the crankcase Before the oil level in the crankcase can fall below a safe limit the Oil Alert system will automatically stop the engine the engine...

Страница 16: ...HP 800 1300 Kitchen Microwave Oven 1000 watt 1000 Coffee Maker 1500 Electric Stove Single Element 1500 Hot Plate 2500 Family Room DVD CD Player 100 VCR 100 Stereo Receiver 450 Color Television 27 500...

Страница 17: ...pstick and then screw the dipstick back into the oil fill hole FILL OIL ON A LEVEL SURFACE Check the oil level BEFORE EACH USE with the generator on a level surface and the engine stopped o Remove the...

Страница 18: ...d keep heat sparks and flame away from the gasoline and engine Refuel only outdoors Wipe up spills immediately Use unleaded gasoline with a pump octane rating of 86 or higher This engine is certified...

Страница 19: ...e switch to return to the ON position Operating the starter motor for more than 5 seconds can damage the motor o Recoil start Pull the starter grip lightly until resistance is felt then pull briskly D...

Страница 20: ...ave a system ground that connects generator frame components to the ground terminals in the AC output receptacles The system ground is not connected to the AC neutral wire AC Applications Before conne...

Страница 21: ...lly shut down In this case wait a few minutes and then reset the circuitry system by turning the circuit breaker to its on position Restart the generator and continue powering the remaining tools and...

Страница 22: ...nomical and trouble free operation It will also help reduce air pollution Improper maintenance or failure to correct a problem before operation can cause a malfunction in which you can be seriously in...

Страница 23: ...djust Combustion Chamber Clean After every 500 hours Fuel tank and filter Clean Fuel Tube Check Every 2 years replace if necessary 1 Service more frequently when used in dusty areas 2 For commercial u...

Страница 24: ...f the engine has not been running for a long time the sediment cup should be cleaned Turn the fuel valve to the OFF position Remove the sediment cup O ring and filter Clean the sediment cup O ring and...

Страница 25: ...rrester Use a brush to remove carbon deposits from the spark arrester screen Inspect the screen for breaks or tears and replace it if necessary Install the spark arrester in the reverse order of remov...

Страница 26: ...bute the oil evenly in the cylinder Reinstall the spark plug Change the engine oil After removal from storage drain the stored gasoline into a suitable container and fill the generator tank with fresh...

Страница 27: ...o the concrete slab using 3 8 diameter expansion anchor bolts not supplied Connect a 6 AWG grounding wire not included from the ground connector 8 on the generator to a grounding rod not included that...

Страница 28: ...fully close the choke Spark plug damaged Readjust gap and dry the spark plug Replace if necessary Carburetor dirty Clean the fuel sediment cup Replace or service the carburetor No electricity to the A...

Страница 29: ...29...

Страница 30: ...Dual Drop Dual Drop Dual Drop Dual Drop Dual Drop Electrical Automatic Voltage Regulation Yes Yes Yes Yes Yes Battery Maintenance Free Maintenance Free Maintenance Free Maintenance Free Maintenance F...

Отзывы: