![TILLOTSON TPP-4500G-A Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/tillotson/tpp-4500g-a/tpp-4500g-a_owners-manual_1116313023.webp)
23
Maintenance Schedule
Remember that this schedule is based on the assumption that your machine will be used for its
designed purpose. Sustained high-load or high-temperature operation, or use in unusually wet or
dusty conditions, will require more frequent service.
REGULAR SERVICE PERIOD (2)
Before
Each Use
First
Month or
20 Hours
Every 3
Months or
50 Hours
Every 6
Months or
100 Hours
Every
year or
300
Hours
ITEM
Performed at every indicated month or
operating hour interval, whichever
comes first
"
Engine Oil
Check
✔
Change
✔
✔
"
Air Filter
Check
✔
Change
✔
(1)
"
Sediment Cup
Clean
✔
"
Spark Plug
Check
✔
Change
"
Spark Arrester
Clean
✔
"
Idle Speed
Check-Adjust
✔
"
Valve Clearance
Check-Adjust
✔
"
Combustion
Chamber
Clean
After every 500 hours
"
Fuel tank and filter
Clean
✔
"
Fuel Tube
Check
Every 2 years (replace if necessary)
(1) Service more frequently when used in dusty areas.
(2) For commercial use, log hours of operation to determine proper maintenance intervals.
Engine Oil Change
Drain the oil while the engine is warm to assure rapid and complete draining.
!
Remove the drain plug and sealing washer, remove the oil filler cap and drain the oil.
!
Reinstall the drain plug and sealing washer. Tighten the plug securely.
!
Refill with the recommended oil and check the oil level.
Wash your hands with soap and water after handling used oil.
Air Filter Service
A dirty air filter will restrict air flow to the carburetor. To prevent carburetor malfunction, service
the air filter regularly. Service more frequently when operating the generator in extremely dusty
areas.