TILLOTSON TPP-4500G-A Скачать руководство пользователя страница 10

 

10 

 

 

 

Ensure  installation  meets  all  applicable  safety,  local  and  national  electrical 
codes.  Have  installation  performed  by  a  qualified,  licensed  electrician  and 
building contractor. 
 
All  electrical  work,  including  the  earth-ground  connection,  should  be 
completed by a licensed electrician. 
 
Any  separate  fuel  storage  or  generator  supply  facility  must  be  built  or 
installed  in  full  compliance  with  all  relevant  local,  state,  and  federal 
regulations. 
 

It  is  recommended  to  use  the  generator  only  in  well-ventilated,  outdoor 
areas.  A  running  gasoline  engine  will  generate  carbon  monoxide,  a 
colorless, odorless gas that, if inhaled, can cause serious injury or death.

 

If  the  generator  is  installed  indoors,  exhaust  fumes  must  be  piped  out  of  the 
building  using  leak-free,  heat  resistant  piping.  Pipes  and  silencer  should  not 
use  any  flammable  materials,  nor  should  they  be  installed  near  the  same. 
Generator  exhaust  fumes  must  be  within  legal  limits  and  installation  must 
always meet local building codes. 
 
 
 
If the generator is installed outdoors, it must be weatherproofed and should be 
soundproofed.  It  should  not  be  run  outdoors  without  protection  to  the 
generator and wiring conduit. 
 
Before  lifting  the  generator,  ensure  the  lift  rigging  and  supporting  structure 
are in good condition, and are rated to lift such a load. 
 
Keep all personnel away from the suspended generator during relocating. 
 
The  supporting  floor/ground  surface  should  be  level  and  strong  enough  to 
safely  hold  the  weight  of  the  generator.  If  the  floor/grounded  surface  is  not 
level,  strong  cross  members  should  be  placed  under  the  full  length  of  the 
generator frame at its low side. 
 
For trailer installation, the generator should be mounted on the center point of 
the  trailer,  over  the  wheels.  The  trailer  must  be  capable  of  supporting  the 
weight of the generator and all contents (tools, etc.). 
 
Install  sound-and  weatherproofing  only  when  it  is  not  raining  or  snowing  to 
avoid trapping moisture within the generator’s area.

 

 

 

Mechanical

 

Содержание TPP-4500G-A

Страница 1: ...ow all safety rules and instructions in this manual before attempting to operate this machine Failure to comply with these instructions may result in personal injury Diagrams within this manual may no...

Страница 2: ...HE GENERATOR 18 STOPPING THE GENERATOR 19 OPERATION INSTRUCTIONS 20 MAINTENANCE 22 STORAGE 25 INSTALLATION 26 TROUBLESHOOTING 27 WIRING DIAGRAM 29 MODEL SPECIFICATIONS 29 The engine exhaust from this...

Страница 3: ...s injury Read them carefully Please read the manual and pay attention to these sections Save These Important Safety Instructions Read and understand all of these safety instructions Be sure to retain...

Страница 4: ...HEN USING AIR TOOLS BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THE RISK OF PERSONAL INJURY Specific Warnings Carbon Monoxide When this tool is running ensure that the area is well ve...

Страница 5: ...MMABE MATERIALS NEAR THE GENERATOR Do not smoke or allow sparks flames or other sources of ignition around the engine and fuel tank Fuel vapors are explosive Keep grounded conductive objects such as t...

Страница 6: ...void body contact with grounded surfaces such as pipes radiators ranges and refrigerators There is an increased risk of electric shock if your body is grounded Do not abuse the power cord for your too...

Страница 7: ...ERATE THE GENERATOR WITH WET HANDS Do not attempt to connect or disconnect load connections while standing in water or on wet or soggy ground Do not touch electrically energized parts of the generator...

Страница 8: ...s Loose clothes jewelry or long hair can be caught in moving parts Avoid accidental starting Make sure the power switch is in its OFF position and disconnect the spark plug wire when not in use Remove...

Страница 9: ...your model Accessories that may be suitable for one generator may become hazardous when used on another generator Servicing Maintain labels and nameplates on the generator and engine These carry impor...

Страница 10: ...exhaust fumes must be within legal limits and installation must always meet local building codes If the generator is installed outdoors it must be weatherproofed and should be soundproofed It should n...

Страница 11: ...loose clothing and jewelry away from moving parts Be aware that when engine parts are moving fast they cannot be seen clearly Keep access doors on enclosures closed and locked when access is not requ...

Страница 12: ...ich could result in electrocution Do not connect to a building electrical system unless a qualified electrician has installed an isolation switch Fire and Burn Hazards The exhaust system gets hot enou...

Страница 13: ...13 GENERATOR COMPONENTS See next page for further explanations...

Страница 14: ...engine Return it gently to prevent damage to the starter When starting the engine by recoil starter set the key switch to the ON position and pull the recoil starter handle Fuel Valve The fuel valve...

Страница 15: ...ne damage caused by an insufficient amount of oil in the crankcase Before the oil level in the crankcase can fall below a safe limit the Oil Alert system will automatically stop the engine the engine...

Страница 16: ...HP 800 1300 Kitchen Microwave Oven 1000 watt 1000 Coffee Maker 1500 Electric Stove Single Element 1500 Hot Plate 2500 Family Room DVD CD Player 100 VCR 100 Stereo Receiver 450 Color Television 27 500...

Страница 17: ...pstick and then screw the dipstick back into the oil fill hole FILL OIL ON A LEVEL SURFACE Check the oil level BEFORE EACH USE with the generator on a level surface and the engine stopped o Remove the...

Страница 18: ...d keep heat sparks and flame away from the gasoline and engine Refuel only outdoors Wipe up spills immediately Use unleaded gasoline with a pump octane rating of 86 or higher This engine is certified...

Страница 19: ...e switch to return to the ON position Operating the starter motor for more than 5 seconds can damage the motor o Recoil start Pull the starter grip lightly until resistance is felt then pull briskly D...

Страница 20: ...ave a system ground that connects generator frame components to the ground terminals in the AC output receptacles The system ground is not connected to the AC neutral wire AC Applications Before conne...

Страница 21: ...lly shut down In this case wait a few minutes and then reset the circuitry system by turning the circuit breaker to its on position Restart the generator and continue powering the remaining tools and...

Страница 22: ...nomical and trouble free operation It will also help reduce air pollution Improper maintenance or failure to correct a problem before operation can cause a malfunction in which you can be seriously in...

Страница 23: ...djust Combustion Chamber Clean After every 500 hours Fuel tank and filter Clean Fuel Tube Check Every 2 years replace if necessary 1 Service more frequently when used in dusty areas 2 For commercial u...

Страница 24: ...f the engine has not been running for a long time the sediment cup should be cleaned Turn the fuel valve to the OFF position Remove the sediment cup O ring and filter Clean the sediment cup O ring and...

Страница 25: ...rrester Use a brush to remove carbon deposits from the spark arrester screen Inspect the screen for breaks or tears and replace it if necessary Install the spark arrester in the reverse order of remov...

Страница 26: ...bute the oil evenly in the cylinder Reinstall the spark plug Change the engine oil After removal from storage drain the stored gasoline into a suitable container and fill the generator tank with fresh...

Страница 27: ...o the concrete slab using 3 8 diameter expansion anchor bolts not supplied Connect a 6 AWG grounding wire not included from the ground connector 8 on the generator to a grounding rod not included that...

Страница 28: ...fully close the choke Spark plug damaged Readjust gap and dry the spark plug Replace if necessary Carburetor dirty Clean the fuel sediment cup Replace or service the carburetor No electricity to the A...

Страница 29: ...29...

Страница 30: ...Dual Drop Dual Drop Dual Drop Dual Drop Dual Drop Electrical Automatic Voltage Regulation Yes Yes Yes Yes Yes Battery Maintenance Free Maintenance Free Maintenance Free Maintenance Free Maintenance F...

Отзывы: