52
SHB10 TIKI
Section 9 |
Control
Menu 4.9 - advanced
Menu 4.9.1 - op. prioritisation
Menu 4.9.2 - auto mode setting
Menu 4.4 - time & date
Menu 4.6 - language
Menu 4.7 - holiday setting
In this menu, we configure advanced functions of the
SHB 10 controller. More information after selecting "
?".
Choose here how long the heat pump should work
with each requirement if there are two or more re-
quirements at the same time. If there is only one re-
quirement the heat pump only works with that require-
ment.
The indicator marks where in the cycle the heat pump
is. If 0 minutes is selected it means that requirement
is not prioritised, but will only be activated when there
is no other requirement. More information after se-
lecting "?".
Set time and date, display mode and time zone here.
Choose the language that you want language 4.6 the
information to be displayed in here.
To reduce energy consumption during a holiday you
can schedule a reduction in heating and hot water
temperature. Cooling, ventilation and pool can also be
scheduled if the functions are connected.
If a room sensor is installed and activated, the desired
room temperature (°C) is set during the time period.
This setting applies to all climate systems with room
sensors.
If a room sensor is not activated, the desired offset of
the heating curve is set. One step is usually enough to
change the room temperature by one degree, but in
some cases several steps may be required. This setting
applies to all climate systems without room sensors.
Vacation scheduling starts at 00:00 on the start date
and stops at 23:59 on the stop date.
Operating mode auto
In this operating mode the heat pump automatically
selects what functions are permitted.
Operating mode manual
In this operating mode you can select what functions
are permitted. You cannot deselect "compressor" in
manual mode.
Operating mode add. heat only
In this operating mode the compressor is not active,
only additional heat is used.
IMPORTANT
If you choose mode "add. heat only" the compressor is
deselected and there is a higher operating cost.
Factory setting:
auto
CAUTION
If you choose to switch off hot water production during
the vacation “periodic increase" (preventing bacterial
growth) are blocked during this time. "periodic increase"
started in conjunction with the vacation setting being
completed.
pump (crossed out = not permitted) and selectable al-
ternatives to the right. To select selectable functions
that are permitted or not, mark the function using the
control knob and press the OK button. More informa-
tion after selecting "?".
When the operating mode is set to "auto", the heat
pump selects when start and stop of additional heat
and heat production is permitted, dependent on the
average outdoor temperature.
In this menu you set the average outdoor temper-
atures, the time (filtering time) during which the av-
erage temperature is calculated. You can also set the
cooling start temperature (if activated).
More information after selecting "?".