![tiki SHB10 Скачать руководство пользователя страница 70](http://html.mh-extra.com/html/tiki/shb10/shb10_installation-and-user-manual_1116016070.webp)
70
SHB10 TIKI
XL8
WM1
XL10
XL14
XL13
XL11
515
345
850
484,5
414
316
218,5
149
34
43
80
13
3
218
Section 13 |
Technical data
13 Technical data
Dimensions and layout of connections
XL2
XL1
PF1
Nameplate
PF2
Plate with the designation of the hydraulic
connections
WM1
Condensate drain from the drip tray
Pipe connections
XL1
Connection, heating medium, supply
Ø22 mm for SHB10-6 and SHB10-12,
Ø28 mm for SHB10-16
XL2
Connection, heating medium, return
Ø22 mm for SHB10-6 and SHB10-12,
Ø28 mm for SHB10-16
XL8
Connection, HW heating medium, supply
Ø22 mm for SHB10-6 and SHB10-12,
Ø28 mm for SHB10-16
XL10
Connection, GW1/2” drain valve
XL11
Connection, safety assembly
Ø22 mm, pressure gauge
XL13
Liquid refrigerant
Connection 1/4" (SHB10-6)
Connection 3/8" (SHB10-12 / SHB10-16)
XL14
Gas refrigerant
Connection 1/2" (SHB10-6)
Connection 5/8" (SHB10-12 / SHB10-16)
Other information
PF1
PF2