HYDRAULIC CONNECTION

ELECTRICAL CONNECTION

The KVR 10 accessory is used to safely drain off most 

of the condensate from the air/water heat pump to a 

frost-free collection point.

For information on hydraulic connection of the KVR 10 

accessory, see the instructions for the KVR accessory.

Length

(m)

P

tot

 (W)

Fuse (F3)

Part no.

1

15

T100mA/250V

718 085

3

45

T250mA/250V

518 900*

6

90

T500mA/250V

718 086

*Fitted at the factory

Plates to be punched-out

Residual-current device RCD

In order to connect the electric KVR accessory:

1.  Open the control panel and punch-out the 

notched plates in the control panel casing under 

the residual-current device.

Connecting the KVR accessory

2.  Attach the residual-current device RCD.

3.  Use fuse (F3) depending on the length of the 

KVR cable in accordance with the below table. 

4.  Connect a residual-current device to terminal 

AA2-X1 under terminal block 5(N) and 6(L).

5.  Connect a residual-current device to terminal 

AA23-X1 to terminal blocks 1(L) and 2(N).

6.  Connect an external heating cable (EB14) to termi-

nal AA23-X1 to terminal blocks: 4 (PE), 5 (N), 6 (L). 

Residual-current 

device RCD

SHK 10

SHK 10

External heating 

cable

Section 12 | 

Accessories

Содержание SHB10

Страница 1: ...09 02 2021 30122 SHB10 TIKI Installation and User manual Indoor module for air to water split systems ...

Страница 2: ......

Страница 3: ...___28 6 Electrical connections__________29 General information______________________29 Connections____________________________30 Settings_______________________________32 7 Commissioning and adjusting_____33 Preparations___________________________33 Filling and venting_______________________33 Circulation pump________________________34 Commissioning__________________________34 Start Guide_________...

Страница 4: ...xperience and knowl edge if they will be supervised or have received instruction concerning safe use of the ap pliance and if they understand the danger involved in its use Children must not play with the appliance Cleaning and basic maintenance of the appliance must not be carried out by chil dren unsupervised The rights to make structural changes are reserved TIKI 2021 This manual contains insta...

Страница 5: ... valve Shut off valves Pressure in the climate system Connectedaccordingtooutlinediagram Hot water Shut off valves Mixing valve Safety valve Electric power supply Connecting communication Perimeter protection Protection indoor unit Building protection Outdoor temperature sensor Room sensor Current sensor Safety circuit breaker Residual current device Setting the thermostat to emer gency mode Misce...

Страница 6: ... able to take the weight of a filled indoor unit Since SHB10 is equipped with condensate drain off system the indoor unit must be installed at the site with sewage system drain CAUTION The SHB10 unit must be hanged on the wall using the included hanger The device can be installed in vertical position only 130mm 130mm 2 Drill the holes in marked points 3 Screw the attachments to the wall using the ...

Страница 7: ...ure sensor BT 3 pc Instalation and user manual SHB10 can be installed in any room protected against temperature drop below 0 C to avoid freezing of the heating medium 800 mm of free space should be ensured in the front of the indoor unit All servicing of SHB10 can be performed from the front 1 Unscrew the bolts from the lower edge of the front cover 1 2 Tilt the cover at the edge making sure that ...

Страница 8: ...10 X10 X0 X1 FA2 FA3 GP12 AA27 AA2 X4 AA2 X4 AA2 X15 AA2 K2 EP2 BT12 CM1 BP4 BT15 BT63 BT3 BT30 EB1 FD1 AA23 AA3 K1A K3A FA1 XL11 SF1 X2 AA7 BT71 BT25 QN10 XL8 WM1 XL10 XL14 XL13 Section 3 Design of the indoor unit XL2 XL1 UB4 PF3 PF4 PF2 PF1 UB3 ...

Страница 9: ... Input board AA23 Communication board AA7 Extension card AA27 Relay board FD1 Thermal circuit breaker FA1 Miniature circuit breaker protecting the indoor unit FA2 Miniature circuit breaker protecting the outdoor unit FA3 Miniature circuit breaker protecting the STB and power EB1 Electric additional heat Various SF1 Controller switch Pipe connections XL1 Connection heating medium supply XL2 Connect...

Страница 10: ...tion heating medium supply Ø22 mm for SHB10 6 and SHB10 12 Ø28 mm for SHB10 16 XL2 Connection heating medium return Ø22 mm for SHB10 6 and SHB10 12 Ø28 mm for SHB10 16 XL8 Connection HW heating medium supply Ø22 mm for SHB10 6 and SHB10 12 Ø28 mm for SHB10 16 XL10 Connection GW1 2 drain valve XL11 Connection safety assembly Ø22 mm pressure gauge XL13 Liquid refrigerant Connection 1 4 SHB10 6 Conne...

Страница 11: ...5 28 CAUTION All high points in the climate system must be equipped with air vents CAUTION Ensure that incoming heating medium is without pol lution When using a private well it maybe necessary to supplement with an extra water filter CAUTION In the installation before the SHB 10 a particulate fil ter should be used dedicated for heating installations The filter will protect the unit against pollu...

Страница 12: ...mum climate system volumes The heat pump installation requires an appropriate volume of heating medium approx 10l kW heat pump power and a minimum undisturbed flow In case of an insufficient amount of heating medium in the installation an additional buffer vessel must be used which will ensure adequate system volume see subsection Minimum climate system volumes An insufficient flow in the central ...

Страница 13: ...lutions e g excess relief valve low loss header buffer in parallel or open heating loops Remember to always keep the minimum required flow and volume of the sys tem see the sections Minimum system flow and Buffer vessel Removing condensate Connecting the refrigerant pipe not included NOTE It is absolutely necessary for the appropriate safety valve to be fitted directly on the cold water supply pip...

Страница 14: ... 10 unit where the pipes are to be routed The drawing below shows the pipe outlets to choose from Take care to ensure no water or pollutants enter the refrigerant connection pipe Pollutants in the pipes risks damage to the heat pump Bend the pipes with the maximum bending radi us at least R100 R150 Do not bend the pipes A B Zawó Zaw A B CAUTION Gas shielding must be used when soldering External di...

Страница 15: ...d for compression and dry ing of the completed pipeline TIP To achieve a better end result and speed up creation of the vacuum please follow the below points The pipelines should have the correct diameter and length Drain the system to 4 mbar and fill it with dry nitrogen to atmospheric pressure AMS 10 is delivered complete with the refrigerant required for the installation of refrigerant pipes wi...

Страница 16: ... C Max temperature in the unit SHB 10 70 C Maximum hot water temperature 60 C Minimum temperature ext operation of the unit 20 C Minimum temperature ext cooling operation 15 C Max supply temperature compressor 58 C Min cooling supply temperature 7 C Max cooling supply temperature 25 C Minimum volume climate system during heating cooling 50 l 80 l 100 l 150 l Max flow climate system 0 29 l s 0 38 l...

Страница 17: ... BT7 sensor in the place that will show the highest temperature in the tank Whereas the BT6 sensor in 1 3 1 2 of the coil height meas ured from the lower extreme point The location of the sensors is shown in the domestic hot water con nection diagram DHW tank should be connected to a water system with a water pressure recommended by the tank manufacturer If the pressure at the in let of cold water...

Страница 18: ...n system Connecting the 4 pipe cooling operation system In the 2 pipe cooling degree minutes are counted ac cording to BT25 Docking an additional climate system Additional accessories and the connection options and methods for these are described in the instructions for AXC 30 and ECS 40 ECS 41 The principle of a 2 pipe system is to use the same circuit for cooling and or heating 2 pipe cooling di...

Страница 19: ...lume of the central heating system is increased using a buffer vessel you will need to check the system volume and possibly increase the volume of the existing expansion vessel CAUTION If connection AA3 X7 is used for another purpose an additional AA5 accessory card is required to connect the hot water circulation pump control Hot water circulation Connecting the control of the hot water circulati...

Страница 20: ...source Buffer vessel Fan coil Section 4 Pipe connections NOTE The installation diagrams presented in the manual are examples and do not include all system components They do not replace the design of the building s central heating system Basic diagram with serial connection of a buffer tank Basic diagram with parallel connection of a buffer tank Optional Filterball EB101 BT1 BP4 HS1 GP12 BT63 BT25...

Страница 21: ...a buffer tank Diagram of heating and 4 pipe cooling EB101 BT1 BP4 HS1 GP12 BT63 BT25 BT71 QN10 P BT12 BT3 P BT15 BT7 BT6 SHB10 XL1 XL2 GP11 BT2 BT3 QN25 GP20 AA25 EB101 BT1 BP4 HS1 GP12 BT63 BT25 QN10 P BT12 BT3 P BT15 BT7 BT6 SHB10 XL1 XL2 GP11 BT2 BT3 QN25 GP20 AA25 GP10 BT71 BT1 BP4 HS1 GP12 BT63 BT25 QN10 QN12 P BT12 BT3 P BT15 BT7 BT6 GP11 XL1 XL2 BT64 GP13 GP10 EB101 SHB10 BT71 ...

Страница 22: ...erably a concrete foundation If concrete slabs are used they must rest on asphalt or shingle The concrete foundation or slabs must be posi tioned so that the lower edge of the evaporator is at the level of the average local snow depth however no lower than 300 mm Supports and fastenings on the page are available in the AMS 10 manual in the Accessories section The AMS 10 heat pump should not be pos...

Страница 23: ...ree or alternatively indoors subject to local rules and regulations Use a siphon for installations where air circula tion may occur in the condensation water drain age pipe The insulation must be tightly fitted to the bot tom of the condensation water trough In case of scrapping the product is dismantled by performing the above actions in reverse order Lift by the bottom panel instead of a pallet ...

Страница 24: ...oute the pipe downward from the air water heat pump The condensation water drainage pipe must have a siphon to prevent air circulation in the pipe The installation length can be adjusted by the size of the siphon Drain into the gutter CAUTION Bend the hose to create a siphon see illustration LEK Frostfritt djup Water seal Frost free depth Water seal LEK From air water heat pump siphon siphon Depth...

Страница 25: ... AMS 10 8 AMS 10 6 30º 30º 188 25 750 24 61 340 48 51 12 150 223 310 580 61 150 32 880 88 418 380 19 49 104 Nad 43 93 640 40º 40º 12 148 34 89 51 44 290 84 510 327 201 18 800 12 71 352 313 5 1 4 2 AMS 10 outdoor unit Section 5 ...

Страница 26: ...HB10 TIKI AMS 10 12 388 190 60 580 200 262 38 40 50 370 410 20 40 60 15 60 20 970 50 55 15 845 10 50 110 195 242 279 50 27 50 52 195 110 100 40 51 36 50 150 70 15 50 40 103 15 AMS 10 outdoor unit Section 5 ...

Страница 27: ...HB10 TIKI AMS 10 16 970 50 55 15 1300 113 46 10 50 27 50 50 50 110 195 195 612 624 50 50 110 325 190 60 580 200 265 50 150 70 15 50 40 38 40 50 370 410 20 40 103 60 15 15 60 20 AMS 10 outdoor unit Section 5 ...

Страница 28: ...wever the free space from the front must be 100 cm for future servicing Minimum space the least disturbance for neighbours The sound level may be affected by walls bricks differences in ground level etc therefore the values given should only be considered as suggested levels In order to reduce the noise level avoid direct air out let to places that are particularly sensitive to excessive sound lev...

Страница 29: ...t FA3 Miniature circuit breaker protecting the STB and power FD1 Thermal circuit breaker UB1 Cable grommet UB2 Cable grommet UB3 Cable grommet UB4 Cable grommet K2 Alarm relay AA2 Main board AA2 X15 Terminal block low voltage AA2 X4 Terminal block low voltage AA27 Relay board X2 6 Electrical connections X10 X0 BT30 AA23 AA3 FD1 X1 K1A K3A FA2 FA3 UB1 UB3 UB4 UB2 FA1 SF1 AA7 AA27 K2 AA2 AA2 X15 AA2...

Страница 30: ...ectrical diagram see subsection Electri cal wiring diagrams Connections CAUTION To prevent interference unscreened communication cables and or sensor cables to external connections must not be laid at a distance less than 20 cm from high voltage cables CAUTION The electrical system to which the device will be connect ed should be built in accordance with current regulations CAUTION In the case of ...

Страница 31: ...Miniature circuit breaker X0 X0 Remove the bridge to use dual tariff control Insert a bridge in or der to connect the 230V power supply IT IS FORBIDDEN TO IN STALL BRIDGES AT THE CONNECTION OF LINES L2 AND L3 Section 6 Electrical connections Protection FA2 FA3 FA1 Connecting SHB 10 and AMS 10 The device connecting cable should be connected to the power supply terminal block TB in AMS 10 and to the...

Страница 32: ...ds of the heating cooling circuits in operation The adjustment range is 5 65 C Please note how ever that for underfloor heating the setting should be min 20 C max 35 45 C to maintain comfort in the room and efficient operation of the system 5 4 3 2 1 SHK 200S SHK 200S 6 BT1 BT1 AA3 X6 The outdoor temperature sensor BT1 included should be connected to the SHB 10 unit via terminal block AA3 X6 1 and...

Страница 33: ...g medium vent the system 4 Close the vent valve after the system has been completely filled 5 Check the pressure gauge on which an increase in pressure will be visible Fill the system to the required pressure 1 5 2 5 then close the filling valve The maximum operating pressure of the system is 2 5 bar 6 Start the climate system circulation pump The automatic vent valves located on the heating cooli...

Страница 34: ...ings The start guide ensures that start up is carried out correctly it cannot be bypassed The start guide can be started later in menu 5 7 During the start guide the reversing valves are opera tional in order to help vent the heat pump 1 Set the switch SF1 on the controller to I 2 Follow the instructions in the display s start guide If the start guide does not start when you start the controller s...

Страница 35: ... ther consult the help menu or read the user manual C Option setting Enter settings for the system here D Help Menu In many menus there is a symbol which indi cates that extra help is available To view the help text 1 Use the control knob to select the help symbol 2 Press the OK button The help text often consists of several windows that you can scroll between using the control knob Commissioning ...

Страница 36: ...luminated and the status lamp illuminates yellow The status lamp indicates the status of the con trol module It lights green during normal operation lights yellow in emergency mode lights red in the event of a deployed alarm The OK button is used to confirm selections of sub menus options set values page in the start guide The back button is used to go back to the previous menu change a setting th...

Страница 37: ... the display The following symbols can appear in the display dur ing operation Symbol Opis This symbol appears by the infor mation sign if there is information in menu 3 1 that you should note These two symbols indicate whether the compressor in the outdoor unit or additional heat in the installation is blocked via con troller These can for example be blocked depending on which op erating mode is ...

Страница 38: ...finished writing mark OK and press the OK button 1 Turn the control knob until one of the arrows in the top left corner at the page number has been marked 2 Press the OK button to skip between the steps in the start guide To advance in the menu system select a main menu by marking it and then pressing the OK button A new window then opens with sub menus Select one of the sub menus by marking it an...

Страница 39: ...g 1 3 2 cooling 1 3 3 ventilation 1 1 9 advanced 1 9 1 curve 1 9 1 1 heating curve 1 9 1 2 cooling curve 1 9 2 external adjustment 1 9 3 min flow line temp 1 9 3 1 heating 1 9 3 2 cooling 1 9 4 room sensor settings 1 9 5 cooling settings 1 9 6 fan return time1 1 9 7 own curve 1 9 7 1 heating 1 9 7 2 cooling 1 9 8 point offset 1 The ERS additional equipment is necessary ...

Страница 40: ... 1 temporary lux 2 2 comfort mode 2 3 scheduling 2 9 advanced 2 9 1 periodic increase 2 9 2 hot water recirc 2 3 INFO 3 1 service info 3 2 compressor info 3 3 add heat info 3 4 alarm log 3 5 indoor temp log 2 The accessory AXC 30 is required if the output AA3 X7 is occupied ...

Страница 41: ...act 4 1 8 4 tariffperiods electricity 4 1 8 6 tariffper ext shuntadd 4 1 8 7 tariff per ext step add 4 1 8 8 tariff periods 4 1 10 solar electricity 5 4 2 op mode 4 3 my icons 4 4 time date 4 6 language 4 7 holiday setting 4 9 advanced 4 9 1 op prioritisation 4 9 2 auto mode setting 4 9 3 degree minute set ting 4 9 4 factory setting user 4 9 5 schedule blocking 4 9 6 schedule silent mode 3 The POO...

Страница 42: ... 15 GBM communicationsmodule12 5 3 16 humidity sensor 13 5 3 21 flow sensor energy meter 14 5 4 soft in outputs 5 5 factory setting service 5 6 forced control 5 7 start guide 5 8 quick start 5 9 floor drying function 5 10 change log 5 11 slave settings 5 11 1 EB101 5 11 1 1 heat pump 5 11 1 2 chargepump GP12 5 11 2 EB102 5 11 3 EB103 5 11 4 EB104 5 11 5 EB105 5 11 6 EB106 5 11 7 EB107 5 11 8 EB108...

Страница 43: ...s More information after selecting In this menu there is possibility to change settings for the essential settings of the heating system More information after selecting Factory setting presettings Factory setting radiator Factory setting 15 0 DOT C In this menu it is possible to activate additional con nected accessories More information after selecting Factory setting hot water prod 1 18 Languag...

Страница 44: ...ssible to edit the minimum flow temperature of the heating system More information after selecting Factory setting climate system 1 20 C In this menu it is possible to edit the maximum flow temperature of the heating system More information after selecting Factory setting climate system 1 55 C In this menu it is possible to edit the heating curve specified for the SHB 10 unit More information afte...

Страница 45: ...thout rooms ensors installed and activated Setting range 10 do 10 Factory setting 0 In this menu you can select the operating mode for the SHB 10 unit More information after selecting Factory setting auto In this menu it is possible to activate alarm actions More information after selecting Factory setting decrease room temp inactive deactivate hot water inactive Reminder to complete the checklist...

Страница 46: ...rve shows the heating and cooling curves for your house The task of the curve is to give an even indoor temperature regardless of the outdoor tem perature and thereby energy efficient operation It is from these heat curves that the heat pump s control computer determines the temperature of the water to the system the supply temperature and therefore the indoor temperature Select the curve and read...

Страница 47: ... never calculates a temperature lower than that set here If there is more than one climate system the setting can be made separately for each system ADVICE Wait 24 hours before making a new setting so that the room temperature has time to stabilise If it is cold outdoors and the room temperature is too low increase the curve slope by one increment If it is cold outdoors and the room temperature is...

Страница 48: ...ds of the year More information after selecting Menu 2 HOT WATER The Hot water menu is used to adjust the settings for domestic hot water The user has the option of editing temperatures and operating modes for hot water For the menu HOT WATER there are several sub menus Status information for the relevant menu can be found on the display to the right of the menus Menu 2 1 temporary lux Activation ...

Страница 49: ...est possible amount of hot water In this mode the immersion heater may be partially used to heat hot water which may in crease operating costs Menu 2 3 scheduling Here you can program the hot water temperature for two different time intervals throughout the day Scheduling is activated deactivated by ticking untick ing activated Set times are not affected at deactiva tion More information after sel...

Страница 50: ...information of the menu is displayed to the right of the menu Information about the heat pump s actual operating sta tus e g current temperatures etc can be obtained here No changes can be made The information is on several pages Turn the control knob to scroll between the pages A QR code appears on one side This QR code indicates serial number product name and limited operating data Information a...

Страница 51: ... most carbon neutral at the time More information after se lecting The heat pump operating mode is usually set to auto It is also possible to set the heat pump to add heat only but only when an addition is used or manual and select yourself what functions are to be permitted Change the operating mode by marking the desired mode and pressing the OK button When an operating mode is selected it shows...

Страница 52: ...e but in some cases several steps may be required This setting applies to all climate systems without room sensors Vacation scheduling starts at 00 00 on the start date and stops at 23 59 on the stop date Operating mode auto In this operating mode the heat pump automatically selects what functions are permitted Operating mode manual In this operating mode you can select what functions are permitte...

Страница 53: ... after selecting All settings that are available to the user including ad vanced menus can be reset to default values here More information after selecting The compressor can be scheduled to be blocked for up to two different time periods here When sched uling is active the actual blocking symbol in the main menu on the heat pump symbol is displayed More information after selecting Factory setting...

Страница 54: ... settings can be made for the control mod ule in the sub menus economy Setting range start temp economy 5 50 C Factory setting start temp economy 39 C Setting range stop temp economy 5 50 C Factory setting stop temp economy 43 C normal Setting range start temp normal 5 55 C Factory setting start temp normal 42 C Setting range stop temp normal 5 55 C Factory setting stop temp normal 46 C luxury Set...

Страница 55: ...ressor respectively add heat mode Max diff additional heat can never exceed max diff compressor stop temp per increase Setting range 55 60 C Factory setting 55 C step difference compressors Setting range 0 5 4 0 C Factory setting 1 0 C charge method Setting range target temp delta temp Factory setting delta temp climate system Setting range 5 70 C Factory setting 55 C max diff compressor Setting r...

Страница 56: ...binary stepping inactive Factory setting add type step controlled Factory setting positioning before QN10 REQUIRED normal and speed 1 4 Setting range 0 100 Factory setting normal 75 Factory setting speed 1 0 Factory setting peed 2 30 Factory setting speed 3 80 Factory setting speed 4 100 fuse size Setting range 1 200 A Factory setting 20 A transformation ratio Setting range 300 3000 Factory settin...

Страница 57: ...ner to change between the windows Menu 5 2 system settings Menu 5 2 2 installed slaves Menu 5 2 3 docking Menu 5 1 23 compressor curve NOTE This menu is only displayed if the controller is connect ed to a heat pump with inverter controlled compressor search installed slaves This menu contains several sub menus one for each standard Menu 5 1 22 heat pump testing NOTE This menu is intended for testi...

Страница 58: ...must be installed and activated in the accessories menu 5 2 4 IMPORTANT Menu 5 3 14 is inactive in the factory settings For this menu function to be active the F135 accessory must be installed and activated in the accessories menu 5 2 4 A detailed description of programming the accesso ries can be found in the instructions for the individual accessories A detailed description of programming the ac...

Страница 59: ...ide see page 43 It is possible to start the compressor from here Menu 5 9 floor drying function length of period 1 7 Setting range 0 30 days Factory setting period 1 3 5 7 2 days Factory setting period 4 3 days temp period 1 7 Setting range 15 70 C Default value temp period 1 20 C temp period 2 30 C temp period 3 40 C temp period 4 45 C temp period 5 40 C temp period 6 30 C temp period 7 20 C Set ...

Страница 60: ... the heat pump Factory setting This menu allows setting the rotations with which the GP12 circulating pump is to run in the current op erating mode In auto mode the speed of the feed pump is adjusted automatically to ensure optimal op eration If auto is activated for heating operation you can also make the setting max allowed speed which re stricts the charge pump and does not allow it to run at a...

Страница 61: ... produced The compressors are switched off Charge pump EB101 GP12 and charge pump EB102 GP12 if installed are running Accessories are switched off The heating medium pump is active The emergency mode relay K1 is active Electric module available power 3kW External additional heat is active if it is connected to the emergency mode relay K1 terminal block X1 Ensure that the heating medium circulates ...

Страница 62: ...e display shows informa tion always in English of the most probable update that the update software has selected form the USB memory This information states which product the software is intended for the software version and general infor mation about them If you wish to select another file than the one selected the correct file can be select ed by choose another file start updating Select start u...

Страница 63: ...them later or to copy the settings to another controller Via recover settings you reset all menu settings from the USB memory Here you can choose how current measurement val ues from the controller should be saved onto a log file on the USB memory 1 Set the desired interval between loggings 2 Tick activated 3 The present values from the controller are saved in a file in the USB memory at the set i...

Страница 64: ... system 3 Open the safety valve to remove the created un derpressure IMPORTANT When emptying the side of the heating medium heating system remember that they may contain hot heating medium There is a risk of burns The device is equipped in heating system draining valve XL10 The valve must be fitted with a drain ing hose connected to a floor drain to prevent room flooding ...

Страница 65: ...s can mean that the heat pump s compressor is not running In this case any electrical addition pro duces heat and or hot water If the operational interference is not shown in the dis play the following tips can be used Start by checking the following items The switch s position Group and main fuses of the accommodation The control module s miniature circuit breaker Correctly set load monitor if in...

Страница 66: ...equirement The controller does not call on heating or hot water Compressor blocked due to the temperature conditions Wait until the temperature is within the prod uct s working range Minimum time between compressor starts has not been reached Wait 30 minutes and then check if the compres sor has started Alarm tripped Follow the display instructions CAUTION When commissioning without TIKI air water...

Страница 67: ...o control external 1 to 3 phase loads such as oil burners immersion heaters and pumps Part no 067 309 This accessory is used to supply the building with recovered energy from the ventilation air The device ventilates the building and heats the supply air if nec essary An accessory board for active cooling 4 pipe sys tem extra climate system hot water comfort or if more than four charge pumps are t...

Страница 68: ...itted at the factory Plates to be punched out Residual current device RCD In order to connect the electric KVR accessory 1 Open the control panel and punch out the notched plates in the control panel casing under the residual current device Connecting the KVR accessory 2 Attach the residual current device RCD 3 Use fuse F3 depending on the length of the KVR cable in accordance with the below table...

Страница 69: ...E to the terminal AA2 X4 9 All connections should be made in accordance with the figure below Connection of an additional GP10 pump Diagram with buffer tank connected in parallel and additional circulation pump GP10 L N 1 1 0 2 3 4 PE AA2 X4 SMO Externt PE L N Zewnętrzne SHB 10 AA2 X4 GP10 8 9 10 11 12 13 BP4 HS1 GP12 BT63 B AA25 T25 BT2 BT3 BT71 QN10 QN25 P BT12 BT3 P BT15 SHB10 XL1 XL2 GP20 GP10...

Страница 70: ...on heating medium supply Ø22 mm for SHB10 6 and SHB10 12 Ø28 mm for SHB10 16 XL2 Connection heating medium return Ø22 mm for SHB10 6 and SHB10 12 Ø28 mm for SHB10 16 XL8 Connection HW heating medium supply Ø22 mm for SHB10 6 and SHB10 12 Ø28 mm for SHB10 16 XL10 Connection GW1 2 drain valve XL11 Connection safety assembly Ø22 mm pressure gauge XL13 Liquid refrigerant Connection 1 4 SHB10 6 Connect...

Страница 71: ...ant amount kg 1 5 2 55 2 90 4 0 Max length of refrigerant pipe one way m 30 Refrigerant pipe dimensions Gas pipe ext diameter 12 7 1 2 Liquid line ext diameter 6 35 1 4 Gas pipe ext diameter 15 88 5 8 Liquid line ext diameter 9 53 3 8 Optional pipe connections Right hand side Bottom right hand side back Part no 064 205 064 033 064 110 064 035 Product type Unit SHB10 6 SHB10 12 SHB10 16 Height mm 8...

Страница 72: ...connected compressor not running recommended fuse rating A 20 20 20 20 20 20 25 25 Max operating current and recom mended fuse rating for 1x230 V connection Unit SHB10 6 AMS 10 6 SHB10 12 AMS 10 8 SHB10 12 AMS 10 12 SHB10 16 AMS 10 16 Max operating current compressor A 16 16 20 25 Max operating current of heat pump including 1 5 kW immersion heater compressor running and contactor K1 connected rec...

Страница 73: ...onal average space heating efficiency av erage climate 188 1 31 172 127 174 132 180 138 Water heating energy efficiency average climate 99 99 98 98 Sound power levels LWA indoors dB 35 35 35 35 Nominal heat output Pdesign cold climate kW 4 6 9 10 12 13 15 16 Nominal heat output Pdesign warm climate kW 4 5 8 8 12 12 15 15 Annual energy consumption for space heating cold climate kWh 2 694 4 610 6 26...

Страница 74: ...ing energy efficiency class of the package average climate A A A A A A A A Seasonal space heating energy efficiency of the package cold climate 147 120 143 112 146 115 148 117 Seasonal space heating energy efficiency of the package warm climate 256 183 229 184 233 189 239 193 A D for product space heating A G for package space heating A F for product domestic hot water The reported efficiency of t...

Страница 75: ... Tj 2 C Pdh 3 26 Tj 7 C Pdh 1 8 kW Tj 7 C Pdh 4 72 Tj 12 C Pdh 2 7 kW Tj 12 C Pdh 6 47 Tj biv Pdh 4 7 kW Tj biv Pdh 1 88 Tj TOL Pdh 4 1 kW Tj TOL Pdh 1 77 Tj 15 C ifTOL 20 C Pdh kW Tj 15 C ifTOL 20 C Pdh Bivalent temperature Tbiv 7 C Min outdoor air temperature TOL 10 C Cycling interval capacity Pcych kW Cycling interval efficiency COP cyc Degradation coefficient Cdh 0 99 Max supply temperature WT...

Страница 76: ...C Pdh 2 6 kW Tj 7 C Pdh 4 42 Tj 12 C Pdh 3 7 kW Tj 12 C Pdh 5 93 Tj biv Pdh 6 6 kW Tj biv Pdh 1 83 Tj TOL Pdh 5 9 kW Tj TOL Pdh 1 86 Tj 15 C ifTOL 20 C Pdh kW Tj 15 C ifTOL 20 C Pdh Bivalent temperature Tbiv 8 6 C Min outdoor air temperature TOL 10 C Cycling interval capacity Pcych kW Cycling interval efficiency COP cyc Degradation coefficient Cdh 0 97 Max supply temperature WTOL 58 C Power consum...

Страница 77: ... 61 Tj 12 C Pdh 5 0 kW Tj 12 C Pdh 6 25 Tj biv Pdh 9 2 kW Tj biv Pdh 1 90 Tj TOL Pdh 8 1 kW Tj TOL Pdh 1 92 Tj 15 C ifTOL 20 C Pdh kW Tj 15 C ifTOL 20 C Pdh Bivalent temperature Tbiv 7 9 C Min outdoor air temperature TOL 10 C Cycling interval capacity Pcych kW Cycling interval efficiency COP cyc Degradation coefficient Cdh 0 98 Max supply temperature WTOL 58 C Power consumption in modes other than...

Страница 78: ... 68 Tj 12 C Pdh 6 8 kW Tj 12 C Pdh 6 51 Tj biv Pdh 12 7 kW Tj biv Pdh 1 95 Tj TOL Pdh 11 0 kW Tj TOL Pdh 1 95 Tj 15 C ifTOL 20 C Pdh kW Tj 15 C ifTOL 20 C Pdh Bivalent temperature Tbiv 8 C Min outdoor air temperature TOL 10 C Cycling interval capacity Pcych kW Cycling interval efficiency COP cyc Degradation coefficient Cdh 0 98 Max supply temperature WTOL 58 C Power consumption in modes other than...

Страница 79: ... MONITOR A B GND A B GND 29981 PWM 1 GND PWM 1 PWM BT1 BT50 OUTSIDE ROOM 3 3C 5 5D 4 4B 4 4B PWM 2 GND PWM 2 PWM BT25 BT6 AUX1 AUX2 AUX3 BT7 BT71 QN10 GP12 N K1 L 3 5E OPTION OPTION OPTION 5 7E 4 5A 4 4A 3 3F 3 3F 4 3B 4 3B L1 L2 L3 N N PE L1 L2 L3 N N PE 3G10mm 400V 3N AC 50Hz 230V 1N AC 50Hz SUPPLY VOLTAGE X0 8 2A 3 2 PE N L AMS10 8 1C X10 Bridge B02 only for 230V 1AC 50Hz Optional remove the br...

Страница 80: ...27 RELAY CARD X2 X3 X6 X5 3 1 3 1 6 4 6 3 5 2 4 1 510 513 511 514 512 515 011 013 012 014 AA27 X3 1 AA27 X2 1 AA2 K2 AA2 K4 com2 509 509 507 K2 A1 A2 14 11 12 6 3 B K2 507 X7 com1 W102 521 519 522 1 X2 2 4 3 4 519 522 1 2 3 4 5 6 X8 1 2 3 4 5 6 508 X3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 AUX4 AUX4 AUX5 AUX6 X1 ALARM RELAY HONGFA HF115F 29981 ...

Страница 81: ...0V 50Hz 230V 2AC 50Hz 02 04 Blue Black White Brown 022 014 X10 1 2 3 M 1 QN10 SHUTTLE VALVE FLOW LINE M 1 EB101 GP12 L PE N PWM1 GND PWM1 PWM M 1 GP10 L PE N EXT CIRC PUMP OPTION CHARGE PUMP 09 08 07 06 05 L Pe K1 X15 N N K2 PE N K3 010 013 AA2 K4 AA2 K2 AA23 PE AA23 N AA23 L AA7 L AA7 N X3 34 FA1 1 2 3 4 UB 16 UB 15 UB 14 UB 13 WILO YONOS PARA GT15 7 5 PWM1 M 4526976 GEWISS GW90246 MTC60 C10 EMV1...

Страница 82: ...517 518 A B GND X3 X5 X1 1 4 2 5 3 6 510 513 511 514 512 515 com2 X2 W3 com3 K1 ALARM OR COOLING X7 C NO NC X20 1 2 3 4 X21 1 2 3 4 X22 1 2 3 X23 1 2 3 White Brown Green X8 021 BF1 FLOW SENSOR GND B A 12VDC 29981 518058 L 307468 BT1 BT50 BT25 BT71 AUX 2 OUTSIDE SENSOR ROOM HEATING MEDIUM FLOW HEATING MEDIUM RETURN AUX 3 AUX 1 OPTION OPTION 2 7A 3 4E 3 4E 5 6E 5 6E 9 1F 5 6E AA23 X4 3 AA23 X4 2 AA2...

Страница 83: ... BT3 COOLING FLUID PRESSURE CONVERTER L 100687 218552 Sw30 W1939 89 NSK BE046I U005 Danfoss no 061H5121 29981 28986 Next Accesory Card AA5 X4 1 2 3 4 5 6 7 8 GND B A 08 OPTION Brown Blue White Yellow green KVR KIT OPTION RCBO FOR KVR KIT A B GND A B GND L N PE PE 1 2 C10 FB1 30mA 3 4 4 3 1 2 2 1 09 08 09 08 C10 FB1 30mA N N 1 2 2 1 08 09 08 09 RCBO FOR KVR KIT 230V 2AC 50Hz OPTION RCBO FOR KVR KIT...

Страница 84: ...501 031 041 042 032 05 010 037 036 035 AA7 AA7 L AA7 N K1A A1 A2 1 2 8 6 D 3 4 8 6 D 5 6 8 6 D K1A 037 K2A A1 A2 1 2 8 7 D 3 4 8 7 D 5 6 8 7 D K2A K3A A1 A2 1 2 8 8 D 3 4 8 8 D 5 6 8 8 D K3A 011 K2 2 2 C 14 11 12 012 N 1 1 1 1 0 0 PE PE 2 3 4 L 033 015 X1 030 030 FA1 1 FA1 3 AA2 X1 3 X0 L X0 N X0 PE KVR KIT PE OPTION 29981 016 017 30233 03 01 J PE PE 06 3 2D 2 3F 3 2C 3 2F 3 2F 3 2F 2 7B 2 6B 5 5F...

Страница 85: ...016 2AP01 5 3B 6 2D 6 2D 6 2D 3 2 PE N L L1 L2 L3 N N PE 29275 29275 29279 29279 5G2 5mm 30236 30239 Terminal block 30238 Unit housing SIEMENS 5SL6120 6 MCB B20 29978 29271 Contactor strip X10 1 1F L1 L2 L3 N N PE 3G10mm 400V 3N AC 50Hz 230V 1N AC 50Hz SUPPLY VOLTAGE X0 1 2D Bridge B02 only for 230V 1AC 50Hz Optional remove the brigde B01 to separate electrical heaters e g with additional RCD B01 ...

Страница 86: ...86 SHB10 TIKI DATE NEXT SHEET SHEET CHANGES NAME REV Drawing no PCA Display 9 Drawn by Date A 1 2 3 4 5 6 7 8 B C D E F AA4 PCA Display X9 X8 X1 W3 com3 29981 OK 4 5F 027303 Section 13 Technical data ...

Страница 87: ......

Страница 88: ...TIKI HVAC d o o Partizanska cesta 12 3320 Velenje Email servis tiki si www TIKI si ...

Отзывы: