Use and Maintenance Manual - X Series
Page
55
1
st
CHECK AFTER
50 OPERATING HOURS
50 OPERATING HOURS
2
nd
CHECK AFTER
500 OPERATING HOURS
250 OPERATING HOURS
3
rd
CHECK AFTER
1000 OPERATING HOURS
500 OPERATING HOURS
FOLLOWING CHECKS
1000 HOURS OR 1 OPERATION
YEAR
500 HOURS OR 1 OPERATION
YEAR
The fluid state is therefore constantly monitored, thus allowing its use until its features decay. Normally, in the absence of
contaminating agents, the oil is never completely changed, but only occasionally topped-up.
The oil samples (at least 500ml) must be taken with the system at operating temperature.
It is recommended to use new and clean containers.
The samples must be sent to the “bio” oil supplier.
For more dispatch details, contact Your nearest distributor.
Copies of the analysis report must be kept in the check register. This is mandatory.
7.3.3.7
Mix
Mixtures with other biodegradable oils are not allowed.
The remaining amount of mineral oil must not exceed 5% of total filling quantity as long as the mineral oil is suitable for the same
use.
7.3.3.8
Micro-filtration
When making the conversion on second-hand machines, always take into account the high dirt dissolution power of biodegradable
oil.
After conversion, the dissolution of fault-causing deposits in the hydraulic system could occur. In extreme cases, washing the seal
housings can cause greater leaks.
To prevent faults as well as avoid any negative effect on oil quality, after the conversion, it is best to filter the hydraulic system
using a micro-filtration system.
7.3.3.9
Disposal
The biodegradable oil, inasmuch as saturated ester, is suitable for both thermal and material re-use.
It therefore provides the same disposal / re-use options as mineral based old oil.
Such oil can be incinerated whenever local laws allow.
Recycling the oil is preferable to disposal on dumps or incineration.
7.3.3.10
Topping up
The oil must
ONLY EVER
be topped up with the same product.
Note:
Max water contamination is 0.1%.
During oil change or topping up, do not discard the hydraulic oil in the environment.
Содержание Airo X Series
Страница 46: ...Use and Maintenance Manual X Series Page 46 GUARD RAILS FOLDING DOWN SEQUENCE 1 2 3 4 5 6 7 8 9 10...
Страница 70: ...Use and Maintenance Manual X Series Page 70...
Страница 94: ...Uso e manutenzione Serie X Pag 94 045 07 001...
Страница 103: ...Uso e manutenzione Serie X Pag 103 049 07 001...
Страница 112: ...Uso e manutenzione Serie X Pag 112 045 08 011 045 08 012...
Страница 113: ...Uso e manutenzione Serie X Pag 113...
Страница 114: ...Uso e manutenzione Serie X Pag 114...
Страница 115: ...Uso e manutenzione Serie X Pag 115...