background image

3

Safety First!

WARNING: Installation of your TigerStop Product must be done by a person trained in the safe 

design and installation of automation products, and in the safe operation of power equipment. Ensure 

that such installation meets all legally required safety requirements and guidelines, and that proper 

guarding and safety devices are provided on all sides of the equipment to preclude unintended access 

during operation.  Consult with and follow the recommendations of a qualifi ed safety engineer.

WARNING: TigerStop Products are components intended for use in conjunction with potentially 

dangerous machinery. The use of TigerStop Products does not make other machinery safe. TigerStop 

Products are not intended to substitute, in any manner, for safe operating practices in general, or for 

safety features present in other machines designed to make those machines as safe as possible. 

TIGERSTOP PRODUCTS, IF USED OR INSTALLED IMPROPERLY, MAY CAUSE PERSONAL 

INJURY OR DEATH AND SHOULD ONLY BE OPERATED BY PERSONS TRAINED IN THEIR 

SAFE OPERATING PROCEDURES.

 Illustrations of TigerStop Products in use do not show, and are 

not intended to show, all safety features and practices necessary for their safe operation.

GENERAL

WARNINGS

IMPORTANT SAFETY INFORMATION.  READ ALL WARNINGS BEFORE OPERATING THIS PRODUCT.

WARNING: TigerStop Products must be installed in accordance with all local, state, and federal 

regulations. Only personnel properly trained in the safe design and installation of automation 

machinery and related power equipment should install TigerStop Products onto other equipment, to 

ensure a safe and proper work station. TigerStop Products should not be operated without proper 

training, both in the operation of TigerStop Products, and in the operation of related equipment.

INSTALLATION

WARNINGS

IMPORTANT CAUTION: 

The motor box (compartment) contains DC voltage with potentially FATAL amperage. NEVER attempt 

any unauthorized actions inside the motor box.

WARNING: Using a TigerStop interconnect does not relieve you of the responsibility for making sure 

that your saw or other tool has all the necessary safety equipment in place.  All installations must 

meet all legally required safety requirements and guidelines.  Installation and training should be done 

following the recommendations of a qualifi ed safety engineer.

INTERCONNECTS

DANGER: This machine can start, move and stop automatically. Keep hands and loose clothing 

clear of moving parts while operating. Moving parts can crush and cut. When used with a saw or 

other cutting equipment, bodily injury and death may result if operated without safety guards on 

all machines. Do not operate with guards removed. Operators must wear adequate eye and ear 

protection.

OPERATION

DANGER! Don’t get pinched by the push feeder. Keep your hands away when in motion!

Содержание TigerGauge

Страница 1: ...1 2017 TigerStop LLC Installation Guide Installation Guide TigerGauge February 2017 Mk1 ...

Страница 2: ...2 Serial Number TigerGauge Calipers Power Supply Antenna Wireless Receiver 9 Volt Power Supply Serial Cable ...

Страница 3: ...UCT WARNING TigerStop Products must be installed in accordance with all local state and federal regulations Only personnel properly trained in the safe design and installation of automation machinery and related power equipment should install TigerStop Products onto other equipment to ensure a safe and proper work station TigerStop Products should not be operated without proper training both in th...

Страница 4: ... footwear safety glasses ear protection and a dust mask Use only 3 wire extension cords that have 3 prong grounding type plugs and 3 pole receptacles that accept the tools plug for 120VAC Use only 5 wire cords and plugs when using 3 phase DO NOT operate this or any machine under the influence of drugs or alcohol Do not open motor compartment or controller keypad DC Voltage with potentially FATAL am...

Страница 5: ...9 Power ON OFF Zeroing Measuring Transmitting Data Building a Part List Using TigerGauge Advanced Settings 12 Resolution Reference Value Offset Value Direction Auto Power Off Period Restore Screen 4 Second Off Delay 4 Second Calibration Delay Reset Reference Incremental Measurement Access Reference Value Access Offset Value Language TigerGauge Maintenance 17 Charging TigerGauge Replacing TigerGaug...

Страница 6: ...o be connected between the TigerStop controller and the motor box as shown below Note Make sure the cable orientation is connected as shown in the picture If the controller cables are connected backwards the cable shielding will not work properly TigerGauge Calipers I O Panel WARNING Read all instructions before performing any parts installation NEVER power up system while motor box is open ALWAYS...

Страница 7: ...efault the TigerStop password is set to the serial number 4 At the Menu Select screen press one time Next we must change the communication speed setting of the TigerStop I O Panel to match TigerGauge 5 Press the SysInfo soft key to access the System Information menu 6 Press to scroll through the settings Stop when you see IOP Rate To change I O Panel Baud Rate 1 Enter the password and press Note B...

Страница 8: ... access all menu options Enter your TigerStop password and press Note By default the TigerStop password is set to the serial number 4 At the Menu Select screen press 5 Press the SysInfo soft key to access the System Information menu 6 Press to view your serial number and enable code 7 Press A B C and D one after the other 8 Press to erase the enable code when prompted 9 Press STOP to return to the...

Страница 9: ...on for 3 seconds The TigerGauge screen will show a count down and will power up after 3 seconds Hold the power button again for 3 seconds to power down P HOLD 3 Seconds P 3 1 2 P Zeroing 1 Close TigerGauge jaws 2 Hold the Calibrate button for 3 seconds 3 The measurement display will change to 0 000 Note If you are using the Reference Value setting the display will show the reference you have set ...

Страница 10: ...w soft key 4 At the List interface enter the list number you wish to program and press the Edit soft key Note The list number is a memory slot that houses the list You can choose numbers 1 100 5 Select the type of list you would like to program 6 TigerStop will ask you if you want to optimize the list for material yield If you choose no TigerStop will process the list exactly as entered and will N...

Страница 11: ...een for line 1 Take a measurement with TigerGauge and press the transmit button 9 TigerStop will enter the measurement and continue to line 2 Transmit all of your part sizes in this manner 10 Press the Done soft key when all the part sizes are entered ...

Страница 12: ...laces you want TigerGauge to display P Press to scroll through the setting options Inch 01 Measures inches up to two decimal places Inch 001 Measures inches up to three decimal places Inch 1 16 Measures fractional inches in increments of 1 16th of an inch Inch 1 32 Measures fractional inches in increments of 1 32nd of an inch Inch 1 64 Measures fractional inches in increments of 1 64th of an inch ...

Страница 13: ...the selected number Direction Direction toggles the measuring direction Uses this setting if you are measuring inside dimensions P Press to toggle the setting Options Down Measuring outside dimensions Up Measuring inside dimensions Auto Power Off Turns on or off the automatic power down function TigerGauge will power down after a set amount of time This setting works with the Period setting to set...

Страница 14: ...een is turned on TigerGauge will display the last position on the screen When turned off TigerGauge will need to be re calibrated after power up P Press to scroll through the options Options ON TigerGauge displays it s last position on powered up OFF TigerGauge will need to be re calibrated on power up 4 Second Off Delay Sets a 4 second delay before TigerGauge will power off This requires the user...

Страница 15: ... the Reference setting when is pressed Note TigerGauge cannot be zeroed in this mode OFF TigerGauge will zero when you press Incremental Measurement Turns on TigerGauge s incremental measurement mode This allows the user to set a second zero point while measuring to see how far one measurement is from another P Press to scroll through the options Options ON Puts TigerGauge in incremental measureme...

Страница 16: ...TigerGauge will display the Reference value 3 Press to select a number 4 Press to change the selected number Access Offset Value Creates a quick toggle from the measurement screen to the Offset value P Press to scroll through the options Options ON Allows the user to use a quick toggle to access the Offset OFF Turns off the Offset quick toggle Using the Reference Quick Toggle 1 At the measurement ...

Страница 17: ... on screen when it needs to be recharged 1 Connect the AC power supply to a 110VAC power outlet 2 Connect the power jack to the TigerGauge charging port Replacing TigerGauge Batteries 1 TigerGauge has four screws holding the cover in place Remove these screws 2 Remove the TigerGauge cover You will see the batteries mounted inside the cover 3 Replace the batteries Note TigerGauge uses two AA rechar...

Страница 18: ...18 ...

Страница 19: ...19 ...

Страница 20: ...20 12909 NE 95th Stree t Vancouver WA 98682 2426 1 360 254 0661 sales tigerstop com TigerStop B V Holland 31 546 575 171 info tigerstop nl www tigerstop com FIND US ONLINE AT ...

Отзывы: