7
Installing TigerGauge Wireless Receiver
RS232 Serial Port
Power Port
1. Connect the supplied 9 volt power supply from
your 110VAC wall outlet to the TigerGauge
wireless receiver power port.
2. Connect the supplied RS232 serial cable from
the wireless receiver to the port marked “Laser”
on the I/O Panel.
Change I/O Panel Baud Rate
1. From the Ready Screen, press the [Show] soft key to show the menu
options.
2. Press the [Menu] soft key to display the Menu Select screen.
3. TigerStop requires a password to access all menu options. Enter
your TigerStop password and press .
Note: By default, the TigerStop password is set to the serial number.
4. At the Menu Select screen, press
one time.
Next, we must change the communication speed setting of the TigerStop I/O Panel to match
TigerGauge.
5. Press the [SysInfo] soft key to access the System Information menu.
6. Press
to scroll through the settings. Stop when you see “IOP
Rate”.
To change I/O Panel Baud Rate...
1. Enter the password and press .
Note: By default, the TigerStop password is set to the serial number.
2. Press [B] or [C] to toggle the I/O Panel Baud Rate until it is set to
38400 bps.
3. Press the [Done] soft key to save the parameter.
WARNING!
Read all instructions before performing any parts installation!
NEVER
power up system
while motor box is open!
ALWAYS
lock out/tag out TigerStop machinery before installing parts!