17
5. Technical data
Rated voltage:
50 ... 500 V AC/DC
Voltage indication:
high-impedance, direct reading:
LED ≥ 50 V ~ and ≥ 120 V + -
LCD ≥ 50 V backlit
accuracy 2,5 % + 5 digit
low-resistive connected:
additional display symbol for
connected load
Phase / Phase sequence / Polarity:
capacitive, without accessible
electrode
arrows for phase sequence
POL for phase unipolar
tests possible with gloves
voltage type - / ~
Frequency:
0 ... 2000 Hz
Input resistance:
direct (high-impedance):
approx 150 - 190 kΩ
switched (fast start-up): 50 Ω
Current peak value:
direct: < 3,5 mA
switched: 4,6 A / 230 V
Continuity:
0 ... 1000 kΩ
Connectible load:
approx. 1050 W bei 230 V
On-time:
30 seconds
Overvoltage protection:
automatic switch-off
of load at 260 V
Overload protection:
thermo-switch,
thermo-point at > 70°C
Surge voltage strength:
12 kV case insulation to user
12 kV switching mechanism
between test prods
Insulation test voltage :
6 kV unit inspection
of case and line
Overvoltage category :
CAT IV in accordance with
IEC 60664-1 (VDE 0110)
Operating temperature:
-10 ... +55°C
Power supply:
maintenance-free - without battery
test functions voltage,
phase sequence are supplied
from the mains, ,
continuity by Li-accu with
automatic charging function
Casing:
solid rubber EPDM,
unbreakable display cover made of
indestructible polycarbonate IP 65
Protection category:
IP 65, device can be used in moist
environments
Connecting line:
Patented thermo line
Ø 15 mm / 1,8 m
PA-thermo protection meshwork
Maße / Gewicht:
274 x 75 x 47 mm (display part) / 720 g