TIE DOWN 72810 Скачать руководство пользователя страница 6

6

TIE DOWN 

Safety Products Division

800-241-1806   •   404-344-0000  •  www.tiedown.com

E1847, Rev. 9/24/21

Connecting to the Penetrator X3

DO NOT hook Personal Fall Arrest System (PFAS) to any point except a Fall Arrest or Fall Restraint 

Tie-off Anchor Point.

When making connections, only use double-locking snap hooks and double-locking carabiners with this 
equipment.  Only use connectors that are suitable to each application. Ensure all connections are compatible 
in size, shape and strength. Do not use equipment that is not compatible. Ensure that all connectors are fully 
closed and locked.

The Fall Restraint Tie-Off

Two Fall Restraint Anchor tie off’s are located on the top corners of the Penetrator X3 where labeled. The Fall 
Restraint tie off’s DO NOT arrest falls. The user must insure that the Fall Restraint worker is personally equipped 
with lanyards, harnesses, safety lines, etc., when working in conjunction with potential fall arrest workers.

Do not attached fall restraints to the hoisting ring locations.

Do Not allow the fall restraint users to work close to any roof edge.

FALL ARREST TIE-OFF

The three Fall Arrest Tie Off points are located on the lower side of the Penetrator X3 in bright red, under of the 
stay clear guard. The user must insure that the lanyards and harness are properly attached.

IMPORTANT: DO NOT allow workers to cross paths (cross lines) at anytime! Fall Restraint/Fall Arrest 

lines must never cross over each other. Crossed lines will cause the unit to not function as intended. 

Failure to maintain clear lines may cause a accident or death.

DO NOT OPERATE DAMAGED EQUIPMENT. DO NOT OPERATE EQUIPMENT THAT HAS BEEN MODIFIED.

(Please use the Inspection and Maintenance Log contained within the instructions manual )

Fall Arrest

Connection Points

Hoisting Point

Fall Restraint

Connection Point

Hoisting Point

Fall Restraint

Connection Point

Содержание 72810

Страница 1: ...Nickel which is known to the State of California to cause cancer For more information go to www P65Warnings ca gov WARNING This product can expose you to chemicals including Nickel which is known to t...

Страница 2: ...Separately Rescue Winch Assembly Purchased Separately Mounting Pins Mounting Frame Spike Engagement Tube Tension Spring Retainer Penetrator Spikes 800 241 1806 404 344 0000 www tiedown com PX3 Fall A...

Страница 3: ...ss connectors and a body harness and must include a deceleration system or suitable combinations Note that a PFAS does NOT prevent a fall from occurring The Penetrator X3 can be used as an anchorage i...

Страница 4: ...UIREMENTS Verify that the surface that the Penetrator X3 will be used on is capable of supporting both the unit and personnel using it Inspect that the entire area to determine if the working surfaces...

Страница 5: ...t Path Cart Path 8 ft Min 15 ft 45 45 45 45 Unprotected Edge or Leading Edge 16 Feet Safe Work Zone Unprotected Edge or Leading Edge 30 Feet Maximum Safe Work Zone After 15 feet the maximum Range of U...

Страница 6: ...equipped with lanyards harnesses safety lines etc when working in conjunction with potential fall arrest workers Do not attached fall restraints to the hoisting ring locations Do Not allow the fall re...

Страница 7: ...X3 should not be used by persons whose ability or alertness is impaired by fatigue intoxicating beverages illegal or prescription drugs or any other physical cause that exposes the user or others to...

Страница 8: ...the rigging gear DO NOT hook to the fall arrest or fall restrain shackle safety line connectors when lifting the cart 3 1 2 Carriage Bolts Install the Permanent Winch Mount From the back side of the P...

Страница 9: ...d to use a 1 2 impact wrench for this part of the installation There are two options for installing the permanent roller guide bracket assembly 1 Access the nylock nut by working from the top inside a...

Страница 10: ...cue hook should pass under the roller and about the bottom of the roller bracket WARNING Be careful not to come in contact with the five penetrating spikes 3 1 4 Clevis Pin 3 1 2 Carriage Bolts Safety...

Страница 11: ...A WORKER WHEN NOT BEING PROPERLY CONNECTED TO AN APPROVE ANCHORAGE CONNECTION CAN RESULT IN SERIOUS INJURY INCLUDING DEATH Workers must be properly trained in the use of the Tie Down Rescue System PR...

Страница 12: ...d off to the Penetrator X3 Using a rescue pole attach the hook cable to the fallen worker If the cable length and ground conditions allow it is recommended to lower the worker safely to the ground If...

Страница 13: ...deployment as the result of an fall incident make certain that the rescue procedure has been successfully completed The five penetrating spikes will be somewhat buried into the roof after activation F...

Страница 14: ...tems This certificate declares that the above standard s was met by the requirements of such standard s Testing was performed under normal operating measures The results of testing apply only to the s...

Страница 15: ...on the employee to 1 800 pounds 8 kN 1910 140 d 1 ii Bring the employee to a complete stop and limit the maximum deceleration distance the employee travels to 3 5 feet 1 1 m 1910 140 d 1 iii Have suff...

Страница 16: ...l Cart Parts Date Corrective Action Taken Penetrator X3 Device Frame Free of Rust Frame Welded Connections Mounting Pins 2 Penetrator X3 Spikes Free of Damage Spike Guard Shield Present Anchor Shackle...

Отзывы: